My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
24323
>
2300 - Underground Storage Tank Program
>
PR0231947
>
COMPLIANCE INFO_2006 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:49:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2010
RECORD_ID
PR0231947
PE
2361
FACILITY_ID
FA0004345
FACILITY_NAME
JAHANT FOOD N FUEL STOP
STREET_NUMBER
24323
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00516019
CURRENT_STATUS
01
SITE_LOCATION
24323 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\24323\PR0231947\COMPLIANCE INFO 2006 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2010
QuestysRecordDate
2/10/2017 12:43:22 AM
QuestysRecordID
3335338
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: ` Inspection Date: <br /> Facility aad(.dresss�: *Ce pQ //,y q UST# b <br /> tAWW <br /> CAAW11, CA <br /> 197 <br /> Facility Contact: Title: Phone: 9 0 l <br /> 333-2811 <br /> Monitoring Panel: Piping system: Overfill prevention: <br /> Pressurized 11Suction ❑GravityMcchanical ❑Audible/visual <br /> Inspection type: Violations: <br /> Routine Monitorin Certification 11hpstallation ❑Other: MI-RDetmt ❑M2-RPrev ❑M-3 Both <br /> # Code Section VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> V=Violation;RV=Repeat Violation V <br /> I HSC 25284 Permit too erste <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b)& c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4, HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 6 Monitoring Program(Monitoring&Response Plan)is current and approved by the local agency. <br /> 6 CCR 2712 1) Monitoring Ian is onsite. <br /> 7 CCR 2712 6 Maintenance&monitoring records Ml <br /> 8 CCR 2643 d Daily monitoring of suction piping(pre-January, I, 1984) <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present (Ml) <br /> I l CCR 2630 d UST system monitoring equipment is properly located to detect a leak Ml <br /> 12 HSC 25291 6 UST system monitoring equipment isoperational (M2 <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping&UDC is present Ml <br /> 14 CCR 2631 a Primary containment is product tight <br /> is HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detectors are installed Ml <br /> 18 CCR 2635(b)(1) Spill container (M2) <br /> 19 CCR 2635(b)(2) Overfill prevention system M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&20 containment <br /> 21 HSC 25291 (e) Water in 20 containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases Ml) <br /> a 23 CCR 2715 Designated Operator.ft Statement from UST owner; (c-e)Monthly inspection; t)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638 a) Annual line leak detector test (Ml) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test M1) <br /> 28 CCR 2661 Repair for tank/pi ing has had tightness test M2) <br /> 29 CCR 2643 a Biennial tightness test of gravity pipingre-Janus 1, 1984 <br /> 30 CCR 2643 d) Triennial line test for conventional suction piping( re-Janna I, 1984) Ml) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 b) Permit to temporarily close UST system <br /> 35 HSC 25298 c) Permit to close UST system <br /> 36 1 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) Illegal abandonment of UST system <br /> 38 1 Other: <br /> EHD IN O • PHONE: ge"It UIC <br /> /) Seotic system: <br /> "J -Serves 220 people/day <br /> RECEIVED BY: TITLE: —Receives other than sanitary waste <br /> Other disposal methods16� : <br /> C.J —Dry wells/French Drains <br /> EHD 23-02-002 REV 05/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.