My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
24323
>
2300 - Underground Storage Tank Program
>
PR0231947
>
COMPLIANCE INFO_2006 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:49:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2010
RECORD_ID
PR0231947
PE
2361
FACILITY_ID
FA0004345
FACILITY_NAME
JAHANT FOOD N FUEL STOP
STREET_NUMBER
24323
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00516019
CURRENT_STATUS
01
SITE_LOCATION
24323 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\24323\PR0231947\COMPLIANCE INFO 2006 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2010
QuestysRecordDate
2/10/2017 12:43:22 AM
QuestysRecordID
3335338
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> Vaporless 99 LD-2000 Addendum <br /> 6.0 Test Results and Limitations <br /> The performance parameters for the 99 LD-2000 are summarized in Table 3. <br /> Probability of DetectionR,,) <br /> The 99 LD-2000 was correct in its determination of a leak for all of the leak tests. The estimated <br /> PD of a 3 gal/h leak is 100%with an upper confidence limit of 61 to 100%. <br /> Probability of False Alarm(PFA) <br /> The 99 LD-2000 was correct in its determination of a tight pipeline for all of the fight tests. The <br /> estimated PFA is 0%with a lower confidence limit of 0 to 39%. <br /> Time to Conduct a Test <br /> All of the tests were completed in under one minute with one exception. One of the tests required <br /> 20 minutes to complete due to a temperature differential extreme that was present during the test <br /> (See Table 1). <br /> Maximum Line Size <br /> The EPA protocol allows pipeline leak detection methods to be used on pipelines with up to <br /> twice the volume of that used in the evaluation. If the EPA protocol is used to calculate the <br /> performance parameters, the 99 LD-2000 can be used on rigid pipelines up to 170 gallons and <br /> flexible pipelines up to 39.5 gallons. <br /> Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.