My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
3550
>
2300 - Underground Storage Tank Program
>
PR0505827
>
COMPLIANCE INFO_2008-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:49:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2015
RECORD_ID
PR0505827
PE
2361
FACILITY_ID
FA0007030
FACILITY_NAME
VALLEY PACIFIC HWY 99 CARDLOCK
STREET_NUMBER
3550
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17916043
CURRENT_STATUS
01
SITE_LOCATION
3550 S HWY 99
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\3550\PR0505827\COMPLIANCE INFO 2008-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Te%phone:(209)468-3420 Fax:(209)468-3433 Web:www.s*gov.o[g/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> VALLEY PACIFIC HWY99 CARDLOCK 209 948-9412 March 31 2015 <br /> Facility Address: CERS ID: <br /> 3550 S HWY 99 STOCKTON CA 95215 1 10182167 <br /> Inspection Contact Title: <br /> Phone: <br /> Mike EliasonCardlock Manager (209 993-8793 <br /> Inspection Type: Prom: <br /> ROUTINE INSPECTION -O eratin Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> Inspection Photos Sam lin James AbbottCardlock Technician <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Richard Thomas 12/05/2015 James Abbott 05/15/2015 <br /> Service Technician Manufacturer's Training <br /> Veeder-Root Level 4 12/10/16 VMI Tester 12/29/16 <br /> California ode o egu ahons H =Health antl afely ode CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Connected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ❑V ❑R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ■V ❑R ❑COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ■V ❑R ❑COS <br /> 105 HSC 25286(c) Current BOE number not submitted ❑V ❑R ❑COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ❑V ❑R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V ❑R ❑COS <br /> 108 1 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ■V u R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V ❑R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ❑V ❑R ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V ❑R ❑COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days ❑V ❑R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ❑R ❑COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well ❑V ❑R ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test ❑V ❑R ❑COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V ❑R ❑COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V ❑R ❑COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> 122 HSC 25299 Documents were falsified or misrepresented ❑V ❑R ❑COS <br /> 123 CCR 2661 Permit to repair UST system not obtained ❑V ❑R ❑COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V ❑R ❑COS <br /> Received by Inspector: /fin Phone: Date: <br /> (initiaQ: (/r STACY RIVERA, Senior REHS ,`Y�S'4�\ (209)468-3440 03/31/2015 <br /> Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.