Laserfiche WebLink
0 0 <br /> San Joaquin County DIRECTOR <br /> PQ N Donna Heran, REHS <br /> Environmental Health Department ASSISTANT DIRECTOR <br /> 600 East Main Street Laurie Cotulla,REHS <br /> y L aii s ' Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> " Carl Borgman,REHS <br /> • Mike Huggins,REHS,RDI <br /> Website: www.sjgov.org/ehd Margaret Lagorio,REHS <br /> �IFOR <br /> Phone: (209) 468-3420 Robert McClellon, REHS <br /> Fax: (209) 464-0138 Jeff Carruesco,REHS, RDI <br /> January 9,2009 Kasey Foley, REHS <br /> Reliable Petroleum Services, Inc. <br /> 521 Branding Iron St. <br /> Oakdale,CA 95361 SENT VIA MAIL <br /> Re: Arch ARCO AM-PM,4855 S.Hwy. 99 East Frontage Rd., Stockton CA <br /> The permit(SR0056271)for the enhanced vapor recovery phase 11 upgrade on the underground <br /> storage tank system(UST)at the above referenced site has been approved with the following <br /> conditions: <br /> Conditions of approval: <br /> 1. Contact the local fire department,city building department and the San Joaquin Valley <br /> Air Pollution Control District for any applicable permits. <br /> 2. Any changes shall be submitted to the San Joaquin County Environmental Health <br /> Department(EHD)for approval prior to commencing work.All new addenda supercede <br /> the previous ones. <br /> 3. All components must be certified by an independent testing organization and labeled as <br /> required by the organization. (UL,ULC,ANSI,API,ASTM, etc. See California Code of <br /> Regulations(CCR),Title 23 Chapter 16 Table B for complete list). The component must <br /> bear the appropriate mark as required by the independent testing organization. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid,current contractor's licenses issued by the <br /> Contractors State License Board(may be issued to the installation company),and <br /> b. All valid, current California UST certificates issued by the International Code <br /> Council(ICC),that are applicable to the work being performed, and <br /> c. A valid,current certificate of training from the manufacturer(s)of the <br /> component(s)being tested,repaired, or serviced; <br /> and <br /> d. Each person installing or testing any component must hold a certificate of <br /> training from the manufacturer of that component. <br /> 5. Before the alarm history is cleared,a current printout must be created and available for <br /> EHD inspection.Inspection may occur during the functionality test. <br />