Laserfiche WebLink
TST EARLY STOP:DISABLED L12:89 ANNULAR <br /> LEAK TEST REPORT FORMAT • TRI-STATE (SINGLE FLOAT) • LIQUID SENSOR ALMS <br /> NORMAL CATEGORY : ANNULAR SPACE L I :FUEL ALARM <br /> L I :SENSOR OUT ALARM <br /> L I :SHORT ALARM <br /> L13:89 FILL ISD SITE ALARMS <br /> TRI-STATE (SINGLE FLOAT) ISD GROSS PRES FAII <br /> CATEGORY : PIPING SUMP ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> L14:89 TURBINE ISD VP PRES FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD HOSE ALARMS <br /> CATEGORY : STP SUMP ALL:FLOW COLLECT FAIL <br /> LIQUID SENSOR SETUP <br /> - - - - - - - - - - - - R2:DISP 3-4 <br /> L15:91 ANNULAR TYPE: <br /> L 1 :DISP 5-6 TRI-STATE (SINGLE FLOAT) STANDARD <br /> TRI-STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE NORMALLY CLOSED <br /> CATEGORY : DISPENSER PAN <br /> TANK #: NONE <br /> L16:91 FILL <br /> L 2:DISP 3-4 TRI-STATE (SINGLE FLOAT) LIQUID SENSOR ALMS <br /> TRI-STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP L 2:FUEL ALARM <br /> CATEGORY : DISPENSER PAN L 2:SENSORHORT AOUT ALARM <br /> L17:91 TURBINE <br /> TRI-STATE (SINGLE FLOAT) ISD SITE ALARMS <br /> L 3:DISP 1-2 CATEGORY STP SUMP ISD GROSS PRES FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD DEGRD PRES FAIL <br /> CATEGORY : DISPENSER PAN IISD SD VAPORESR LEAK <br /> FAIL <br /> ISD HOSE ALARMS <br /> L 4:DISP 11-12 ALL:FLOW COLLECT FAIL <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN R 3:DISP 1-2 <br /> TYPE: <br /> STANDARD <br /> NORMALLY CLOSED <br /> L 5:DISP 9-10 <br /> TRI-STATE (SINGLE FLOAT) 2 WIRE CL SENSOR SETUP TANK #: NONE <br /> CATEGORY : DISPENSER PAN - - - - - - - - - - - - <br /> C 1 :87 FILL SUMP LIQUID SENSOR ALMS <br /> DISCRIM. INTERSTITIAL L 3:FUEL ALARM <br /> L 6:DISP 7-8 CATEGORY PIPING SUMP L 3:SENS0R OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 3:SH0RT ALARM <br /> CATEGORY : DISPENSER PAN <br /> ISD SITE ALARMS <br /> ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL <br /> L 7:DISP 17-18 ISD VAPOR LEAK FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD VP PRES FAIL <br /> CATEGORY : DISPENSER PAN <br /> ISD HOSE ALARMS <br /> ALL:FLOW COLLECT FAIL <br /> L B:DISP 15-16 R 4:DISP 11-12 <br /> TRI-STATE (SINGLE FLOAT) EXTERNAL INPUT SETUP TYPE: <br /> CATEGORY : DISPENSER PAN - - - - - - - - - - - - STANDARD <br /> NONE NORMALLY CLOSED <br /> TANK #: NONE <br /> L 9:DISP 13-14 <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN LIQUID SENSOR ALMS <br /> L 4:FUEL ALARM <br /> L 4:SENSOR OUT ALARM <br /> L 4:SHORT ALARM <br /> L10:87 ANNULAR <br /> TRI-STATE (SINGLE FLOAT) ISD SITE ALARMS <br /> CATEGORY ANNULAR SPACE ISD GROSS PRES FAIL <br /> OUTPUT RELAY SETUP ISD DEGRD PRES FAIL <br /> - - - - - - - - - - - - ISD VAPOR LEAK FAIL <br /> L11 :87 TURBINE R I :DISP 5-6 ISD VP PRES FAIL <br /> TRI-STATE (SINGLE FLOAT) TYPE: ISD HOSE ALARMS <br /> CATEGORY : STP SUMP STANDARD ALL:FLOW COLLECT FAIL <br /> NORMALLY CLOSED <br />