My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TS7393-05 • Page_2_of_2_ <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑ Pressure ® Vacuum ❑ Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: DIGITAL MANOMETER Equipment Resolution: <br /> Tank#RECLAIM Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes ®No ❑ Yes ❑ No ❑Yes ❑No ❑Yes ❑No <br /> Tank Capacity: GOOo GALLON <br /> Tank Material: FIBERGLASS — <br /> Tank Manufacturer: OW <br /> CORNING <br /> Product Stored: RECLAIM LIQUIDS <br /> Wait time between applying <br /> pressure/vacuum/water and 15 MIN <br /> starting test: <br /> Test Start Time: 9:45 AM <br /> Initial Reading 7"HG <br /> Test End Time: 10:45 AM _ <br /> Final Reading(Rr): T'HG _ <br /> Test Duration: I HOUR <br /> Change in Reading(Rr-Ri): 0"HO <br /> Pass/Fail Threshold or Criteria: 0"HG <br /> I est Result;. ® Pass D Fail . Pass ❑`Fail ❑ Pass ❑Fail O Pass ❑Fail <br /> Was sensor removed for testing'? H Yes ❑No ❑NA D Yes ❑ No ❑NA ❑Yes❑No ❑NA ❑Yes ❑ND ❑NA <br /> Wassensor properly replaced and ®Yes ❑No ❑NA ❑ Yes ❑No ❑NA ❑Yes❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to lestinb and recommended Jollow-up fir jailed tests) <br /> RECLAIM TANK ANNULAR PASSED THE REQUIRED SB989 REQUIREMENTS. NO REPAIRS <br /> ARE NEEDED AT PRESENT TIME. <br /> ' Seco, ry containment- stems�vhe�the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> rret;n. f!`0lifnnri0 r`.vir nF Anaulatinnc Tidn 91 Cnr/inn <br /> Loon 'IVILNHNNUTANB ,LIVS TTOTV29916 YVd 9V:LT 9009/VT/TT <br />
The URL can be used to link to this page
Your browser does not support the video tag.