Laserfiche WebLink
TS7393-05 • • Page_2 of 3 <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: ❑Piping Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ®Pressure ❑ Vacuum ❑Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: ANALOG DIAL GAUGE Equipment Resolution: <br /> Piping Run# Piping Run# Piping Run# Piping Run# <br /> SUPPLY <br /> Piping Material: FIBERGLASS <br /> Piping Manufacturer: A.O. SMITH <br /> Piping Diameter: 6 INCH <br /> Length of Piping Run: APPROX. 30 FEET <br /> Product Stored: RECLAIM FLUID <br /> Method and location of TEST BOOTS <br /> piping-run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and 15 MIN <br /> starting test: <br /> Test Start Time: 9:15 AM <br /> Initial Reading(RD: 5 PSI <br /> Test End Time: 10:15 AM <br /> Final Reading(RF): 5 PSI <br /> Test Duration: I HOUR <br /> Change in Reading(RF-Ri): 0 PSI <br /> Pass/Fail Threshold or 0 PSI <br /> Criteria: <br /> Test Result: 0 Pass ❑Fail ❑ Pass ❑ Fail ❑ Pass ❑Fail ❑ Pass ❑ Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> SECONDARY PIPING PASSED THE REQUIRED 1 HOUR TEST AT 5 PSI. TEST BOOT ON THE <br /> TANK SIDE WAS REPAIRED BY IN HOUSE TECHS.NO FURTHER REPIRS ARE NEEDED AT <br /> PRESENT TEVE. <br />