My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.� SAN JOAQUIN COUNTY .� <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www siaov Orolehd/unitiii.htfnl <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility 7-Eleven <br /> tom, 4501 N Pershing Ave, Stockton Oct 10, 2011 <br /> Name title: PI1OAa'951-6745 <br /> co 11� Ramey Gill store manager <br /> Inspection DfRoutire RCMmilarirg System Certification <br /> n Irrstagalion ❑Complakrt-IDIk a other: <br /> Type: <br /> (Authority HSC 25289) Grerited by Ramey Gill Time, store manager <br /> Consent for Xinspec�on XSampImg XPhotos Overfill xme&arvcal ❑AudibleNiwal <br /> kanit«irg Veeder-Root TLS-350 Piping Xpressreaea Dsuawn oc>�r Prevention: <br /> Panel: System: <br /> UST_ 4 - 5- - - - — — ------------ ----------- ---------- --- - -- -- - - - - - - — - — <br /> ---Product- - ._87-0dane _ _-91-octane_. -_ <br /> ICC E». violations: ❑Mt-Release Detection C M2-Release Prevention 1,M3-Both <br /> o�ga��tl Michael Holkko Date: 2-2-12 <br /> IccExp- Mainin ens VR X-11-3-12, VMI X-2-8-12 <br /> Te Site Service Joe Mesa Date: 5-5-13 Training. <br /> TeSite <br /> Y <br /> VIOLATIONS <br /> HSC=CaliMriia Flealth and t Code:CCR=Capfomia Code of R Mations <br /> / c1 C2 M Code section Ci-Class 1 valafioo;C2=Class 2 violation;M=Minor violation <br /> .' FBe Revbavr <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> HSC 25284(aX3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> 103 monitor the tanks tem <br /> 104 HSC 25292.2 Current financial responsibility documents rat on file with Ole Environmental Health Department(EHD) <br /> 105 CCR 2711 Current United Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring 8 Response Plans)is not aarent or approved by the EHD <br /> 107 CCR 2632(d)(1XC) Plot plaNsite map not submitted or tails to completely stow where rn nitorkig is performed <br /> 108 CCR 2637 Secondary containment(a)lest not perfomned;(e)test repod not submitted Will 30 days;(f)test notification <br /> not rovided to the EHD at least 48 hours nor to condu i the test <br /> Mon ori equipment rxrtificaton:(a)not performed annually;(d)test report nd submitted within 30 days; <br /> 109 CCR 2638 (e)test nolifiration not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> ne lacemenl,glibration,or certification (Mt) <br /> 110 HSC 25291(6 Annual line leak detector test not performed <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed a postOve shutdown or fail safe not present (?At) <br /> 113 CCR 2715(x) Failed to inform the EHD of a charge of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> rmit conditions <br /> Enhanced leak detection(ELD)testing not performed on a system located within 1000'of pudic well,or <br /> 116 HSC 25292.5 failures not re aired and retested <br /> 117 CCR 2661 Permit to repair UST system rat obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system charged <br /> 119 HSC 25298(b) Permit to temporarity Gose UST system not obtained <br /> 120 HSC 25298(c) Permit to Gose US7 system not obtained <br /> On Site Records <br /> Maintenance 8 monitoring records not maintained 3 years,cathodic protection records for ir%z years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> 201 CCR 2712(b) (2)monitoring equipment calibration and maintenance records;(3)resuhs of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other in <br /> ui ment, round water elevations,or other test results; 6 results of invento readin s and reconciliations <br /> 202 CCR 2712(1) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that(c)did not escape secondary containment and cleaned up within eight hours IM1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not re rted to the EHD within 24 hours <br /> lex <br /> Inapemr <br /> Garrett Backus (209) 468-2986 <br /> EHD 23-02 Rev 08/01/11 papa 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.