Laserfiche WebLink
0711412010 1421 Containirlent Solutions (FAv'Q145425020 R,007M8 <br /> Hydrostatic monitoring system helps <br /> guard against leaks and liabilities. <br /> Normal Conditions CONCaETEmAFnCPAD Containment Solutions recommends the Hydrostatic <br /> The reservoir liquid Monitoring System for double-wall tanks because of its <br /> level will be stable U ^avnge . ESEgvola superior leak detection capability. By filling the ca • <br /> both the inner and uam t4seesoa cavity <br /> �-srrceenesFavo�n between the inner and outer tank walls with a non- <br /> Thecuttanks <br /> ery are tight uowor.evc� , hazardous liquid, hydrostatic pressure Is continuously <br /> The reservoir sensor applied to both the primary and secondary tank, This <br /> will activate an alarm Ad system Is capable of detecting tank leaks in either the <br /> if the reservoir drains primary or secondary tank walls for all installed <br /> or overfills. odtl64EAxnu conditions. <br /> . Po�u <br /> The HydrUNK <br /> ostatic Monitoring System provides <br /> continuous leak detection while avoiding false alarms <br /> Inner-Wall Breach caused by changes in product temperature, product <br /> Monitor fluid drains level, tank deflection under loads, or groundwater <br /> into the primary tank t55Embogn9aNa, conditions. <br /> causing the reservoir <br /> liquid level to drop Precision Tank Test Capability <br /> and activate an alarm. <br /> Mr <br /> No petroleum pro ? :.,y "- ap�NAu me Hydrostatic Monitoring System,with a stand pipe, <br /> c ducts escape from the r.':' can also serve the dual function of a precision tank test. <br /> primary tank to The system has been Independently tested and <br /> contaminate the annu- <br /> statistically validated to meet the EPA and National Fire <br /> m lar space. Protection Association's criteria as a precision tank test. <br /> Using a stand pipe, the system has been shown to be <br /> capable of detecting leaks as small as 0.10 gallons per <br /> Outer-Wall y.^'P. r'4 .'P. <br /> hour with a 99.9%probability ofdatectionand less than <br /> Breach a 1.2% probability of a false alarm. <br /> Groundwater MOUROwATEa <br /> Below Tank Top � 'SVE` Accessories <br /> If the groundwater is Antifreeze Mixtures <br /> below the tank drains <br /> monitor Fluiduid amine In areas where ambient temperatures or delivered <br /> Into the ground,taus- products may be subjected to freezing conditions, an <br /> Ing the reservoir liquid OMAN antifreeze solution must he used with our Hydrostatic <br /> level to drop and Tank Monitor to avoid potential tank damage. <br /> activate the alarm. Brine Antifreeze Solution <br /> Outer-Wall Breach Our pre-mixed and blended calcium chloride solution <br /> Groundwater provides freeze protection to-40T This non-toxic brine <br /> Over Tank Top aaasnownteN antifreeze can be factory-installed into tanks measuring <br /> a up to 10' diameter and 30,000-g2llon capacity. Its color <br /> If the groundwater is o5. . tracer helps detect hidden damage from shipping or <br /> over the tank top, the <br /> reservoir will fill up jobsite handling. <br /> with groundwater and <br /> activate the high level <br /> alarm on the reservoir ` NTA <br /> sensor, <br />