Laserfiche WebLink
Spill Containment- OPW EVR Thread-on or OPW/POMECO EVR Multi-Port Spill Containers are <br /> certified for installation on the OPW Phase 1 EVR system.All fill ports in these spill containers <br /> _ feature enhanced IDK-2100-EVR vapor tight drain valves that exceed the EVR requirements far <br /> a maximum vapor leak rate of 0.17CFH at 2.0 inches H2O. The vapor return spill containers <br /> feature a,permanent plug installed in the drain ports, as per EVR requirements. <br /> _ Overfill Prevention -The OPW 6150-40OC-EVR Series Overfill Prevention Valves are certified for <br /> 1 installation on theOPWPhase 1 EVR system. The vapor tight EVR 61SO's are designed to provide <br /> positive shut-off of product delivery, before an overfill condition occurs, per EPA requirements, <br /> I without intervention from the transport driver. The valve features a sealed float pivot and a <br /> threaded lowe tube connection,and exceeds the EVR requirement for a maximum vapor leak <br /> r° rate of 0.17CFH at 2.0 inches H2O. The 61 SO-EVR Series Valve is installed in the base of the OPW <br /> EVR Spill Container with the patent pending 61JSK Jack Screw device. This configuration allows <br /> liquid in the spill container to be drained directly into the drop tube, thereby isolating the drain <br /> valve from the tank ullage, eliminating a notorious leak point in previous systems. <br /> 1 - Tank Bottom Protector- The OPW/POMECO 6111-1400 Tank Bottom Protector is EVR certified <br /> for installation at the bottom of the overfill prevention valve drop tube to help prevent the <br /> underground storage tank from sustaining damage from erosion or tank gauging sticks. <br /> i <br /> Ball Float and 233 Extractor-The OPW 53VML Ball Float, 233 Extractor and <br /> oealr <br /> 61T Fill Drop Tube configuration can be installed as an alternative to the 6150 <br /> =` Overfill application. The installation of the Ball Float/Drop Tube system is <br /> identical to the 61 SO Overfill Valve on the OPW Phase I Vapor Recovery System. <br /> Rotatable Swivel Adaptors (Fill and Vapor) - OPW EVR Rotatable Swivel Adaptors are certified <br /> for installation on the fill and vapor ports on the OPW Phase 1 EVR system. OPW Swivel Adaptors <br /> provide 360 degrees of rotation of any product or vapor recovery elbow to prevent the adaptors <br /> from loosening on the spill container risers. OPW Swivel Adaptors exceed the EVR requirement to <br /> maintain a minimum 360-degree rotation with an average static torque not to exceed 108 inch- <br /> pounds (9 foot-pounds). The enhanced po pet system on the DPW 61VSA-EVR vapor swivel <br /> adaptor provides a vapor tight seal w p <br /> P g when closed per EVR requirements. <br /> P <br /> Adaptor Tool -An OPW 615A-TOOL is required to ensure proper installation of DPW Rotatable <br /> ill <br /> I Swivel Adaptors, spill containers and threaded riser adaptors, per EVR requirements. The <br /> t r <br /> 61 SA-TOOL includes provisions for the use of a torque wrench to facilitate accurate installation <br /> 9s, and testing <br /> Dust Caps (Fill&Vapor) = DPW EVR Dust Caps are certified for installation on <br /> l OPW EVR Certified Rotatable Adaptors. DPW EVR Certified Dust Caps feature <br /> ( � enhanced ribbed seals and increased sealing forces to provide a bubble-tight <br /> seal, per EVR requirements. Available inburatuff or low-profile metal models. <br /> ' s <br /> Threaded Riser Adaptor(Face Seal Adaptor) -An OPW FSA-400 Threaded Riser Face Seal <br /> u Adaptor is required to provide a flat;true sealing surface on threaded pipes where a gasket seal <br /> exists per EVR requirements. The FSA-400 is installed on the fill pipe riser below the spill <br /> container to provide a true sealing surface for the drop tube flange on the 61 SO-40OC-EVR <br /> l - Overfill Prevention Valves, The FSA-400 is also required on tank gauging risers,though is <br /> _ I optional on vapor risers and rotatable adaptors. <br /> Pressure Vacuum Vent- The OPW 623V Pressure Vacuum Vent is certified for installation on the <br /> OPW Phase 1 EVR system. The 623V's are installed on the top of the ventes <br /> i <br /> p p for underground <br /> fuel storage tanks. The vent cap and internal wire screen are designed to protect the tank vent <br /> _a lines against intrusion and blockage from water, debris or insects.A normally closed poppet in <br /> i the valve opens at a predetermined pressure or vacuum setting to allow the tank to vent The <br /> L. __I 623V exceeds the EVR requirement of a maximum vapor leak rate of 0.17CFH at 2.0 inches H2O. <br />