My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2010 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:08:46 PM
Creation date
11/8/2018 9:52:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2011
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2010 - 2011 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2011
QuestysRecordDate
12/7/2016 6:42:09 PM
QuestysRecordID
3273248
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4u!N. <br /> Iftes, SAN JOAQUIN COUNTY <br /> er ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, CA 95202-3029 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.siaov.oM/ehd <br /> d�IFORN� <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspect' Dat <br /> Facility Address: Servic Request#: <br /> �{'✓P TVA <br /> 0 hits Service Technician's Name: ICC Service Technicianfinstaller Exp.Date: Manufacturer Training: <br /> �t e f0j4 w2ubill1w kbzol (e,7 <br /> 0.10111 <br /> SERVICE SERVICE <br /> _Leak detector Spill bucket ❑ minimum 5 gallon <br /> E] ❑ mechanical Model: ❑ ❑ 1 hour hydrostatic ElIncon TS-STS <br /> ❑ electronic Serial#: <br /> El line test programmed ElCaldwell System ❑ Other <br /> Leak detector <br /> El mechanical Model: Spill bucket ❑ minimum 5 gallon <br /> ❑ ❑ electronic Serial#: ❑ ❑ 1 hour hydrostatic ❑ Incon TS-STS <br /> El line test programmed <br /> ❑ Caldwell System ❑ Other <br /> sensor Primary piping testing at: <br /> El El positive shutdown Model: ❑ psi <br /> ❑ fail safe Serial#: <br /> El NA —minutes <br /> nsorN'l✓ t Secondary containment testing for: <br /> ❑ positive shutdown Model: a UDC(s) Piping <br /> ❑ fail safe Serial#: D tII — Sump(s) UST(s) <br /> ❑ NA <br /> sensor ❑ Testing for the above components are next due by: <br /> ❑ ❑ positive shutdown Model: <br /> ❑ fail safe Serial#: Note: Please be aware that 2°containment components are required to be tested upon <br /> ❑ NA installation,6 months after,and every 36 months thereetler. <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% Corrosion protection dil rI 4 j- <br /> ❑ Overfill prevention (see LG letter 150-1) �❑l Other: see below <br /> EI This UST facility is APPROVED to operate p(I This UST facility is NOT APPROVED to operate <br /> 1 /` x v- 2= tqu.4L{ <br /> 1S`V - <br /> All L <br /> THIS F CILITY I SUBJECT TO REINSPECTION hT ANY TIME At EHD'S CURRENT HOURLY RATE. <br /> EH IRe ed By: Title: <br /> +. <br /> EHO 23-04 kr,�Y UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 10/06/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.