Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> F .w By All Jurisdictions Within the State of California <br /> Authority Cited.,Chapter 6.7,HeW and Safety Code;Chapter 16,Division 3 Title 23, CNKmia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. H more than one monitoring system control panel is installed at the facility,a separate <br /> ceniffication or moon must be prepared for each monitonno system control Panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system ownedoperator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A-General Information <br /> Facility Name:YRC 813 City: TRACY CA Zip:95304 <br /> Site Address: 1535 E PESCADERO AVE Contact Phone No: 993-7946 <br /> Date of Testing/Service: 03/24/2011 <br /> Facility Contact Person: KRIS/ROY <br /> Make/Model of Monitoring System:VR TLS 350 Work Order Number: 2280192 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: W/O NEAR Tank ID: W/O INFIELD <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: 303 <br /> X Piping Sumprrrench Sensor(s). Model: 205 Piping Sumprrrench Sensor(s). Model: 205 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> )( Tank Overfill/High-Level Sensor. Model: FLAPPER Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: - Tank ID: <br /> 71 In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: 409 <br /> )( Piping SumprTrench Sensor(s). Model: 205 X Piping Sump/Trench Sensor(s). Model: 205 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensorls). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> 71 Tank Overfill/High-Level Sensor. Model: FLAPPER Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser Dispenser ID: <br /> Dispenser Containment Sensors) Model: Dispenser Containment Sensor(s) Model: <br /> Shear Valve(s). Shear Valve(s) <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> Dispenser Containment Sensors) Model: Dispenser Containment Sensors). Model: <br /> F1Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Floats)and Chain(s). Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> F] Dispenser Containment Sensor(s) Model: Dispenser Containment Sensors). Model: <br /> ❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): FX System set-up X❑Alarm history report <br /> Technician Name(print): CHARLES FERRUCCI Signature: /iVz�.� — <br /> Certification No.: B37513 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 03/24/2011 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 <br />