My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 11:11:26 AM
Creation date
11/8/2018 9:52:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2017 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
6/16/2017 6:31:32 PM
QuestysRecordID
3443120
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
00! <br />D. Results of Testing/Servicing <br />Software Version Installed: <br />Complete the following checklist: <br />1.4 <br />RECEIVED <br />FEB 2 8 2017 <br />• Yes <br />No* <br />Is the audible alarm operational? YT� <br />IT Yes <br />No* <br />Is the visual alarm operational? <br />• Yes <br />No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />G. Yes <br />No- <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with <br />heir proper operation? <br />IT Yes <br />No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />N/A <br />Yes <br />r No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring <br />system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check <br />• N/A <br />a//thatapplyj Sump/Trench Sensors; r Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? r Yes; r No <br />Yes <br />No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill <br />prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If <br />• N/A <br />o at what percent of tank capacity does the alarm trigger? % <br />IT Yes* <br />No <br />Nas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E below. <br />Yes* <br />• No <br />as liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />s describe causes in Section E below. <br />Product; r Water. If es, <br />• Yes <br />No* <br />Nas monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />• Yes <br />No* IF <br />sI all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />site has dsl sump 1 with a 794380-205 sensor which was tested and passed <br />site has dsl sump 2 with a 794380-205 sensor which was tested and passed <br />replaced 794380-208 sensor in waste oil tank pad sump <br />unable to get the Gear Oil annular out to test. repair and test. <br />Monitoring System Certification Page 3 of 4 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.