Laserfiche WebLink
Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br />MONITORING SYSTEM CERTIFICATION ... - � _ _ <br />ENVIRONMENTAL t- __ALTH <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring <br />system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The <br />owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A- General Information <br />Facility Name: YRC 813 Bldg. No.: <br />Site Address: 1535 E PESCADERO AVE City: TRACY Zip: 95304 <br />Facility Contact Person: CHRIS ROY Contact Phone No.: 209-993-7946 <br />Make/Model of Monitoring System: Veeder Root TLS -350 Date of Testing/Servicing: 2/6/2017 <br />B. Inventory of Equipment Tested/Certified <br />Check the aoorooriate boxes to indicate soecific eouioment inspected/serviced: <br />Tank ID: motor oil - MOTOR OIL <br />Tank ID: waste oil tank pad - WASTE OIL <br />r— In -Tank Gauging Probe. Model: <br />r In -Tank Gauging Probe. Model: <br />W Annular Space or Vault Sensor. Model: 794390409 <br />W Annular Space or Vault Sensor. Model: 794390407 <br />W Piping Sump / Trench Sensor(s). Model: 794380-205 <br />R Piping Sump / Trench Sensor(s). Model: 794380-208 <br />r Fill Sump Sensor(s). Model: <br />r— Fill Sump Sensor(s). Model: <br />F Mechanical Line Leak Detector. Model: <br />r Mechanical Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />r✓ Tank Overfill / High -Level Sensor. Model: flapper <br />r Tank Overfill / High -Level Sensor. Model: flapper <br />Other (sDKifv equipment type and model in Section E on Pae 2). <br />F Other (specify equipment type and model in Section E on Pae 2). <br />Tank ID: <br />Tank ID: <br />r In -Tank Gauging Probe. Model: <br />r In -Tank Gauging Probe. Model: <br />F Annular Space or vault Sensor. Model: <br />r Annular Space or Vault Sensor. Model: <br />r Piping Sump / Trench Sensor(s). Model: <br />r Piping Sump / Trench Sensor(s). Model: <br />F Fill Sump Sensor(s). Model: <br />r Fill Sump Sensor(s). Model: <br />F Mechanical Line Leak Detector. Model: <br />r Mechanical Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />r Tank Overfill / High -Level Sensor. Model: <br />r Tank Overfill / High -Level Sensor. Model: <br />Other (specify ui ment type and model in Section E on Pae 2).. <br />r Other (specify equipment type and model in Section E on Page 2). <br />Dispenser <br />Dispenser <br />ID: <br />ID: <br />F Dispenser Containment Sensor(s). Model: <br />r Dispenser Containment Sensor(s). Model: <br />F Shear Valve(s). <br />r Shear Valve(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />Dispenser <br />Dispenser <br />ID: <br />ID: <br />r Dispenser Containment Sensor(s). Model <br />r Dispenser Containment Sensor(s). Model: <br />F Shear Valve(s). <br />r Shear Valve(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />Dispenser <br />Dispenser <br />ID: <br />ID: <br />F Dispenser Containment Sensor(s). Model <br />r Dispenser Containment Sensor(s). Model: <br />F Shear Valve(s). <br />r Shear Valve(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />-If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to <br />this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of <br />monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; : (✓ System set- <br />up r✓ Alarm history report <br />Technician Name (print): Steve Willems <br />Certification No.: 836743 <br />_ Signature: <br />License. No.: 743160 Class W <br />Testing Company Name: Tanknology Phone No.: (800) 800-4633 <br />Testing Company Address: 110DO N. MoPac Expressway Suite 500 Date of Testing/Servicing: <br />Monitoring System Certification Page 2 of 4 <br />2/6/2017 <br />12/07 <br />