My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 2013-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 1:27:20 PM
Creation date
11/8/2018 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2016
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 2013-2016.PDF
QuestysFileName
COMPLIANCE INFO 2013-2016
QuestysRecordDate
9/7/2017 11:31:40 PM
QuestysRecordID
3629872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.or /q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> E F KLUDT & SONS INC 1126 E PINE ST LODI Aril 06, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS Il,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons. <br /> The 10,000 gallon Trusco syphon tank's red diesel direct-bury spill container failed when tested. All spill containers <br /> shall have a minimum capacity of five gallons and be capable of containing a spill or overfill until it is detected or <br /> cleaned up. Immediately discontinue deposition of petroleum into the 10,000 gallon Trusco syphon red diesel tank <br /> until the component is repaired or replaced by a properly licensed, trained, and certified contractor under permit and <br /> inspection of the EHD. If the spill container can't be replaced immediately, there is a possibility that the sypon red <br /> diesel UST system may be red tagged to prevent fuel inputs. <br /> Note: The drop tube with flapper set at 95% overfill was transferred from the 10,000 gallon Trusco syphon red diesel <br /> tank and placed into the riser of the 10,000 gallon Trusco main red diesel tank. The fill tube of the 10,000 gallon <br /> Trusco syphon red diesel tank was capped off to prevent fuel inputs. <br /> This is a repeat violation, Class II. <br /> 2010 2635(a)(2)(A) Installation and Testing Requirements for All New Underground Storage Tank. <br /> Triennial cathodic protection system certification testing for the sacrificial anodes were last performed on 3-21-06, <br /> 3-26-09, 5-11-12 and was due by March 2015. Testing has not been completed and is one month past due. These <br /> tests are required once every 3 years. The anniversary of this test is March and cannot be postponed to a later month. <br /> Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 5-6-15. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURR ffNTHOURLYRATE. <br /> THIS FACILITY ISS BJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By Received By(printed name and title): Date: <br /> (signature): Stephen Kludt, President — 6' <br /> Inspector Inspector(printed name and title): Inspector Phone: <br /> (signature): ARIS VELOSO, Senior REHS (209)468-3453 <br /> Page 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.