My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 2013-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 1:27:20 PM
Creation date
11/8/2018 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2016
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 2013-2016.PDF
QuestysFileName
COMPLIANCE INFO 2013-2016
QuestysRecordDate
9/7/2017 11:31:40 PM
QuestysRecordID
3629872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> Aris Veloso [EH] <br /> From: Aris Veloso [EH] <br /> Sent: Tuesday, February 10, 2015 4:22 PM <br /> To: 'steve@kludtoil.com' <br /> Subject: CERS corrections needed for 1126 E Pine St Lodi CA <br /> Hi Steve, <br /> I just finished reviewing your 1/6/2015 10:33AM CERS submittal and made of list of corrections needed. <br /> UST rejected via CERS <br /> This UST submittal was rejected by Aris Veloso, REHS, ICC Certified UST Inspector, on 2-10-15. The <br /> following items need to be addressed/corrected: <br /> Racing Fuel Tank Monitoring is Performed Using the Following Method(s) <br /> Monitor Panel Model should be x76s. <br /> Leak Sensor Model # should be LS-3. <br /> Racing Fuel Pipe Monitoring is Performed Using the Following Method(s) <br /> Panel & Leak Sensor Manufacturer should be Veeder Root. <br /> Panel Mode] # should be TLS-350. <br /> MLLD Manufacturer should be Red Jacket. <br /> MLLD Model should be XLP. <br /> Racing Fuel Under Dispenser Containment (UDC) Monitoring <br /> UDC Panel Manufacturer should be Veeder Root. <br /> UDC Panel Model # should be TLS-350. <br /> UDC Leak Sensor Manufacturer should be Veeder Root. <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown should be yes. <br /> Failure/Disconnection of UDC Monitoring System 'Triggers Automatic Pump Shutdown should be yes. <br /> Kerosene UST Tank Information/Monitoring Plan: <br /> Vent, Vapor Recovery (VR) and Riser/Fill Pipe Piping Construction information should be entered. <br /> Kerosene Tank Monitoring is Performed Using the Following Method(s) <br /> Monitor Panel Model should be x76s. <br /> Leak Sensor Model # should be LS-3. <br /> Kerosene Pipe Monitoring is Performed Using the Following Method(s) <br /> Panel & Leak Sensor Manufacturer should be Veeder Root. <br /> Panel Model # should be TLS-350. <br /> MLLD Manufacturer should be VMI. <br /> MLLD Model should be LD2000. <br /> Kerosene Under Dispenser Containment(UDC) Monitoring : <br /> UDC Panel Manufacturer should be Veeder Root. <br /> UDC Panel Model # should be TLS-350. <br /> UDC Leak Sensor Manufacturer should be Veeder Root. <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown should be yes. <br /> Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown should be yes. <br /> Clear Diesel UST Tank Information/Monitoring Plan: <br /> Corrosion Protection <br /> t <br />