My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 2013-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 1:27:20 PM
Creation date
11/8/2018 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2016
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 2013-2016.PDF
QuestysFileName
COMPLIANCE INFO 2013-2016
QuestysRecordDate
9/7/2017 11:31:40 PM
QuestysRecordID
3629872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI APR 19 2016 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California 1 2 y MI B 1 <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3,Title 23,California Code of tt31eHr3ltt� .137>, � <br /> e9 b�J <br /> This torte must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: E.F.KLUDT AND SONS CARDLOCK Bldg.No.: <br /> Site Address: 1126 E.PINE ST City: LODI <br /> Zip: 96240 <br /> Facility Contact Person: STEVE Contact Phone No.: (209)368-0634 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-360 Date of Testing/Servicing: 4-7-16 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the aepropriate boxes to Indicatespecific a ui meet ins ectedlserviced: <br /> 20-K CLEAR DIESEL Tank 10-K RED DIESEL <br /> Tank ID: Size: Tank ID: Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG-1 ® In-Tank Gauging Probe. Model: MAGI <br /> ® Annular Space or Vault Sensor. Model: 420 ® Annular Space or Vault Sensor. Model: 420 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ® Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other s eci a ui menl <br /> ( P fy q p type and model in Section E on Page 2). <br /> 10K RED DIESEL SYPHON Tank <br /> Tank ID: Size: Tank ID: Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG-1 ❑ In-Tank Gauging Probe. Model <br /> ® Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 716 Dispenser ID: 9/10 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear ® Shear Valve(s). <br /> E] DispenssererContainment <br /> ainment Floats)and Chain(s). ❑ Dispenser Containment Floahs)and Chain(s). <br /> Dispenser ID: 9-SAT Dispenser ID: 10 SAT!11 SAT <br /> ® Dispenser Containment Sensor(s), Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Floats)and Chain(s). ❑ Dispenser Containment Floats)and Chain(s). <br /> DlspenserlD: 11112 DlspenserlD: <br /> ® Dispenser Containment Sensor(s). Model: 206 ❑ Dispenser Containment <br /> Sensor(s). Model, <br /> ® Shear velvets). ❑ Shear Valve(s). <br /> E] Dispenser containment Floats)and Chain(s). El Dispenser Containment Float(s)and Chain(s). <br /> -if the facility contains more tanks or dispensers,copy this tone. Include information For every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment Identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification Is information(e.g.manufacturers'checklists)necessary to verify that this Information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,i have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(pant): Ed Steams Signature: n d_— <br /> Certification No.: A31048 License Na. ��- <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)7440113 <br /> Testing Company Address: 416 2"d STREET GALT,CA 86632 Date of Testing/Servicing. 4/7/16 <br /> Monitoring System Certification Pagel of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.