My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 2013-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 1:27:20 PM
Creation date
11/8/2018 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2016
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 2013-2016.PDF
QuestysFileName
COMPLIANCE INFO 2013-2016
QuestysRecordDate
9/7/2017 11:31:40 PM
QuestysRecordID
3629872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Calif0mia95205-6232 <br /> Telephone: (209) 468-3420 Fax:(209) 468-3433 Web:www siaov ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name; Facility Address: <br /> E F KLUDT& SONS INC Date:1126 E PINE cT i_nr <br /> A ri107. 2016 <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases m secondary piping do not Flow to a collection sump <br /> 322 CCR 2636(f)(2) ❑V ❑R ❑COS <br /> (Q( ) Line leak detector not installed <br /> 323 CCR 2636(f)(2) ❑V ❑R ❑COS <br /> W( ) Leak detector failed to detect a 3.0 gph leak at 10 psi <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep It empty ❑V ❑R ❑COS <br /> ❑V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum ppacity of five gallons <br /> ■V ■R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden ❑V nR ❑COS <br /> ❑V ❑R ❑COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status <br /> 329 CCR 2717.1(g) Tampered with red tag o u ❑COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST o o ❑COS <br /> 331 HSC 25299(t)(2) Tampered with or disabled leak detection devices or alarms nV ❑R ❑COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored ❑V o ❑COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements o o ❑COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements ❑V o ❑COS <br /> ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> J404 <br /> CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve <br /> m o ❑COS <br /> CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed <br /> ❑V ❑R ❑COS <br /> CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) <br /> o m ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation <br /> ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenanceviclation <br /> ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation <br /> ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,of MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> A current Letter of Chief Financial Officer Letter financial responsibility document has not been submitted to the EHD <br /> through CERS. Current financial responsibility documents are required to be submitted annually. Immediately log into <br /> the California Environmental Reporting System(CERS) at http://cers.calepa.ca.gov/, and upload the required <br /> documents. <br /> This is a minor violation. <br /> Page 3 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.