P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 2013-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 1:27:20 PM
Creation date
11/8/2018 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2016
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 2013-2016.PDF
QuestysFileName
COMPLIANCE INFO 2013-2016
QuestysRecordDate
9/7/2017 11:31:40 PM
QuestysRecordID
3629872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> OPW Installation and Maintenance Instructions <br /> OPW 61 SALP EVR (Low Profile) Rotatable Product Adaptors <br /> IMPORTANT: Please read these warnings and use misuse,or improper installation or maintenance. <br /> the assembly instructions completely and carefully OPW shall have no liability whatsoever for special, <br /> before starting. Failure to do so may cause product incidental or consequential damages to any parry, <br /> failure, or result in environmental contamination due and shall have no liability for the cost of labor, <br /> to liquid leakage into the soil,creating hazardous freight,excavation,clean up,downtime, removal, <br /> spill conditions, reinstallation, loss of profit, or any other cost or <br /> charges. <br /> IMPORTANT: Check to make sure the unit is intact For any product certified to California 2001 <br /> and undamaged and all parts have been supplied. standards,OPW warrants that product sold by it are <br /> Never substitute parts for those supplied. Doing so free from defects in material and workmanship for a <br /> may cause product failure. period of one year from date of manufacture or one <br /> year from date of registration of installation not to <br /> WARNING-DANGER: Using electrically operated exceed 15 months from date of manufacture by <br /> equipment near gasoline or gasoline vapors may OPW. <br /> result in a fire or explosion,causing personal injury <br /> and property damage. Be sure that the working area THIS WARRANTY IS IN LIEU OF ALL OTHER <br /> is free from such hazards, and always use proper WARRANTIES, EXPRESS OR IMPLIED, AND <br /> precautions. SPECIFICALLY THE WARRANTIES OF <br /> NOTE:At all times when product is in the storage MERCHANTABILITY AND FITNESS FOR A <br /> tank keep the riser pipe capped, so the vapors PARTICULAR PURPOSE. THERE ARE NO <br /> cannot escape into the environment. WARRANTIES,WHICH EXTEND BEYOND THE <br /> DESCRIPTION ON THE FACE HEREOF. <br /> Notice: OPW products must be used in compliance <br /> with applicable federal, state,and local laws and 61SALP Performance Specifications: <br /> regulations. Product selection should be based on This Rotatable Adaptor has been manufactured and <br /> physical specifications and limitations and tested to the following California Specifications: <br /> compatibility with the environment and material to be Rotatable 360°, Static Torque maximum 108 inch- <br /> handled. All illustrations and specifications in this lbs. <br /> literature are based on the latest production <br /> information available at the time of publication. Preventative Maintenance: <br /> Prices, materials,and specification are subject to Annually, inspect the adaptor for large dents,cracks <br /> change at any time,and models may be or deformation. Replace if necessary. The rotation <br /> discontinued at any time, in either case,without mechanism is not field serviceable. <br /> notice or obligation. <br /> Replacement Parts: <br /> Standard Product Warranty Nipple sealing gasket DPW P/N: H09039M. <br /> OPW warrants that products sold by it are free <br /> from defects in materials and workmanship for a Torque Specification: <br /> period of one year from the date of manufacture by Adapter,4"NPSM,90 ft-lbs minimum to 110 ft-lbs <br /> OPW(ECO products two years from date of maximum. <br /> manufacture.)Proof of purchase may be required. <br /> As the exclusive remedy under this limited warranty, <br /> OPW,will at its sole discretion, repair, replace,or Important: Leave these Installation <br /> issue credit for future orders for any product that Instructions with the Station Operator. <br /> may prove defective within the one year date of <br /> manufacture period(repairs, replacements, or <br /> credits may be subject to prorated warranty for <br /> remainder of the original warranty period,complete <br /> proper warranty claim documentation required.) <br /> This warranty shall not apply to any product that has p TTS LE Cl <br /> been altered in any way,which has been repaired by <br /> any party other than a service representative <br /> authorized by OPW,or when failure is due to ! `. <br /> ENVIPOWENTI <br /> nCOp7T[+c�:�r � <br />
The URL can be used to link to this page
Your browser does not support the video tag.