My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:30 PM
Creation date
11/8/2018 9:53:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\REYNOLDS RANCH\2680\PR0535432\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Franklin Fueling Systems Test Report <br /> Technical Service Engineer/Field Service Engineer site visit report <br /> Site Name and location: <br /> Tucson III Costco #1079 <br /> 1650 East Tucson Marketplace Blvd. <br /> Tucson, AZ <br /> Purpose of visit/ Issue to be resolved: <br /> Test STP-MLD-D installed at site, verify functionality and gather data on performance <br /> with Ultrazol. <br /> Date and time of the visit: <br /> May 19'', 2011 8:00am <br /> People Present: <br /> Greg Perea -- FFS technical service visitor <br /> Tim Hurlocker — Costco <br /> Bill Tegethoff — ANS Distributing <br /> Doug Humpi— Maverick Service Station Maintenance <br /> Adam Smith — Maverick Service Station Maintenance <br /> Armondo Gonzalez— Maverick Service Station Maintenance <br /> FFS equipment involved included: <br /> STP-MLD-D <br /> Pipeline - 40 ft. x 2 in. containing Ultrazol <br /> Description of what was done at the site. <br /> Tested MLD following procedure from manual and leak detector testing apparatus <br /> operation instructions. <br /> Resolution to the visit: <br /> Five separate sample tests for each function taken. <br /> MLD time-to-open (in seconds): MLD sensitivity (ml/ one minute) <br /> 1- :48 (air still in line) 170 ml <br /> 2- :29 (air still in line) 160 ml <br /> 3- :10 (air no longer present) 178 ml = 2.82 gal/h (e gal/h) <br /> 4- :10 no air 168 ml <br /> 5- :09 no air 170 ml <br />
The URL can be used to link to this page