Laserfiche WebLink
SYSTEM SETUP <br /> JUN 20, 2012 10:03 AM <br /> IN-TANK SETUP <br /> COMMUNICATIONS SETUP - - - - - - - _ _ _ <br /> SYSTEM UNITS T 1 :UNLEADED <br /> U.S. PRODUCT CODE t <br /> SYSTEM LANGUAGE PORT SETTINGS: THERMAL COEFF : .000700 <br /> ENGLISHTANK DIAMETER : 119.75 <br /> SYSTEM DATE/TIME FORMAT COMM BOARD : 1 (RS-232) TANK PROFILE 4 PTS <br /> MON DD YYYY HH:MM:SS xM BAUD RATE : 9600 FULL VOL : 19951 <br /> PARITY : ODD 89.8 INCH VOL : 16250 <br /> FAST LANE STOP BIT : I STOP 59.9 INCH VOL : 10025 <br /> 116 ROTH DATA LENGTH: 7 DATA 29.9 INCH VOL : 3790 <br /> LATHROP.CA R9-232 SECURITY <br /> CODE : DISABLED <br /> FLOAT SIZE: 4.0 IN. <br /> SHIFT TIME 1 12:00 AM COMM BOARD : 2 (EDIM ) <br /> SHIFT TIME 2 : DISABLED RS-232 SECURITY WATER WARNING 2•0 <br /> SHIFT TIME 3 : DISABLED CODE : DISABLED HIGH WATER LIMIT: 3.0 <br /> SHIFT TIME 4 DISABLED - <br /> NiflX OR LABEL VOL: 19951 <br /> TANK PER TST NEEDED WRN AUTO TRANSMIT SETTINGS: OVERFILL LIMIT 90% <br /> DISABLED17956 <br /> TANK ANN TST NEEDED WRN AUTO LEAK ALARM LIMIT HIGH PRODUCT 95% <br /> DISABLED DISA953 <br /> AUTO BHIGH WATER LIMIT DELIVERY LIMIT 10%LED 18 10% <br /> LINE RE-ENABLE METHOD DISABLED 1995 <br /> PASS LINE TEST AUTO OVERFILL LIMIT <br /> DISABLED LOW PRODUCT 500 <br /> LINE PER TST NEEDED WRN AUTO LOW PRODUCT LEAK ALARM LIMIT: 99 <br /> DISABLED DISABLED SUDDEN LOSS LIMIT: 99 <br /> LINE ANN TST NEEDED WRN AUTO THEFT LIMIT TANK TILT 0.00 <br /> DISABLED DISABLED PROBE OFFSET 0.00 <br /> AUTO DELIVERY START <br /> PRINT TC VOLUMES DISABLED <br /> ENABLED AUTO DELIVERY END SIPHON MANIFOLDED TAMS <br /> DISABLED T#: NONE <br /> TEMP COMPENSATION AUTO EXTERNAL INPUT ON LINE MANIFOLDED TANKS <br /> VALUE (DEC F ) : 60.0 DISABLED T#: NONE <br /> STICK HEIGHT OFFSET AUTO EXTERNAL INPUT OFF <br /> DISABLED DISABLED <br /> ULLAGE: 90% AUTO SENSOR FUEL ALA <br /> RI'1 LEAK MIN PERIODIC: p% <br /> DISABLED 0 <br /> H-PROTOCOL DATA FORMAT AUTO SENSOR WATER ALARM <br /> HEIGHT DISABLED LEAK MIN ANNUAL p% <br /> DAYLIGHT SAVING TIME AUTO SENSOR OUT ALARM 0 <br /> DISABLED DISABLED <br /> RE-DIRECT LOCAL PRINTOUT - <br /> PERIODIC TEST TYPE <br /> DISABLED STANDARD <br /> EURO PROTOCOL PREFIX <br /> ANNUAL TEST FAIL <br /> S ALARM DISABLED <br /> PERIODIC TEST FAIL <br /> SYSTEM SECURITY RS-232 END OF MESSAGE ALARM DISABLED <br /> CODE : 000000 DISABLED <br /> GROSS TEST FAIL <br /> MAINTENANCE HISTORY ALARM DISABLED <br /> DISABLED ANN TEST AVERAGING: OFF <br /> PER TEST AVERAGING: OFF <br /> TANK CHART SECURITY <br /> DISABLED TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAK OFF <br /> CUSTOM ALARMS DELIVERY DELAY 3 MIN <br /> DISABLED PUMP THRESHOLD : 10.00% <br /> MASS/DENSITY <br /> DISABLED <br />