My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:16 PM
Creation date
11/8/2018 9:53:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\116\PR0523684\COMPLIANCE INFO 2010 - 2012.PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2012
QuestysRecordDate
4/25/2018 3:57:18 PM
QuestysRecordID
3867065
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Secondary Containment <br /> Vacuum Sensing System <br /> Maximize protection with a vacuum <br /> monitored secondary containment :- <br /> system . ._ <br /> A Secondary Containment Vacuum Features and Benefits Facilita[esperiodicoperabilirylesdng <br /> Sensing System for use with Veederu Satisfy Rer((uirernents Leverage Existing Veeder-Root Systems <br /> Root's ATG Systems. Ili, Sc,cndary • Cemfred m meet California's requirement for Uses STP as vacuum source and works with <br /> secondary space monitoring for tanks and lines Red acket and FE STPs <br /> Containment Vacuum Sensing (SCVS) as required by All 2481 <br /> System is designed to detect leaks in double- . Satisfies the requirements for Class I Leak Installs am rite Sisclansand connects to the <br /> walled tanks and piping systems while Detection as deftned by the European cons ole Share wiring <br /> gcosdu wiring <br /> Standard EN 13160-2 Able r-share wiring my safe with other <br /> helping to contain a release of product white • 3rd Party,National Work Group and LG 113 mer-Root intrinsically sate(IS)probes and <br /> under vacuum.The system consists of: listed Interfaces <br /> including tothe Scamp Sor ensor <br /> leak sensors <br /> • Interfaces to the Smart Sensor lnterfaee with <br /> • Vacuum Sensors,connected to tank, Reduce Exposure to Risk Embedded Pressure Module <br /> sum or piping interstices • Alarms when vacuum cannot he maintained Provides for positive shut dawn of pressurized <br /> P P P S or when replenish rate exixeds 851iiers per hour • (nes when required <br /> • ASubmersible Turbine Pump(STP), . The systent alarrns when liquid is detected in Simple installation,no need to mess with brine <br /> to provide a source of vacuum the secondary space <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System 25 degrees C to.70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> The Vacuum Sensor is interlaced Vee console <br /> Root's TLS-350 Monitoring System <br /> via Cable Length:tem via 8 feet TLS-350R/EMC w/BliTLS-350 Plus/EMC Enhanced' <br /> intrinsically safe wiring to provide system Sensor Dimensions: TLS-350/i <br /> status,replenish rate,alarm,and diagnostics"nigh x s"wide z"deep 'Upgrade Note:The Vacuum Sensor System requires <br /> the console to have version 24C software(or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeaer-Root P/N Description <br /> of models: 330020-467 4 Vacuum Sensor Kir for steel tank <br /> 330020-468,469,-470,-471 4 Vacuum Sensor Kit'for fiberglass tanks(4',6,8_,10') <br /> 330020-486 _ 4 Vacuum Sensor Kit'for no tank <br /> • For monitoring double-walled piping 330020-472 3 vacuumsensor Krcrc for steel tank- - _and sum interstices 330020-473,-474,-475,-476 3 Vacuum Sensor Kit'forfberglass tanks(4',6',8',10'2 <br /> P 330020-485 3 Vacuum Sensor Kir for no tank <br /> • For monitoring double-walled steel tank 330020-479 __ 2 vacuum Sensor Kit-for steel tank <br /> interstices(see back page) 330020-481,-482,-aha:484 2 Vacuum Sensor Kir for fiberglass tanks pV,6',a',1(') <br /> 330020-480 2 Vacuum Sensor Kit'for no tank <br /> • For double-walled(fiberglass tanks 330020-495 1 vacuum Sensor Kir for no tank <br /> 857280-100 Vacuum Sensor for piping 8 sumps <br /> These kits differ in the number of vacuum 857280-200 Vacuum Sensor for steel tanks _ <br /> 857280-301 302,-303_,-304 Vacuum8ensor for fbergl9ae tanks(4'68 ?6).__.__ <br /> sensors and the configuration of associated 330020-448_ _ __ Mounting Kn <br /> liquid sensors. An inline kit mounted liquid 332217-001 _ Relief vane Assembly <br /> sensor is used for Vacuum Sensors <br /> 332250-001 Smart Sensor w/Embetlded Pressure Sensor Module(7 Channell•_- - --- <br /> monitoring piping and sumps. An external Accessories Part Description QuaMRy/Length Part Number <br /> liliquid sensor(to be installed in the secondary 1(4 NPT Barbed_Rlli 9s._--_.. __. - 3. —_. __ 330020.487 <br /> q Y 1/4"NPT Barbed Fittings 15 330020-488 <br /> space al the bottom of the tank) is provided 1/4"NPT Barbed Fittings 25 33002&489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1- _ _ _ --576008-657 <br /> Vacuum Hose 25' 25 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 50' _ - 332310-002 <br /> Vacuum Hose 100' 1W 332310-003 <br /> 3-Vvay Ball Valve 1 _ 576008-649 <br /> Schrader Valve Barbed Fitting 3 330020 496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> Kitsnuade mounting bracket,6'of vacuum hose,relict valve assembly Of reptimi and the afxroprbte number of teed sensors, <br /> 3-way ball vara,barbed fittings and hose clamps so Mat each vacuum sensor can monitor a single lank,sump or piping interstices. <br /> The Vacuum Sensing Syslere rehires one 7 channel Smart Sensor Interface with Embedded Pressure Modula.A channel Smart <br /> Sensor Modules file 329366-0u)can be used for Vacuum sensors eight and above. <br /> For more information call: 1-888-561-7942 <br /> VEEDER-ROOT <br />