EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:16 PM
Creation date
11/8/2018 9:53:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\116\PR0523684\COMPLIANCE INFO 2010 - 2012.PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2012
QuestysRecordDate
4/25/2018 3:57:18 PM
QuestysRecordID
3867065
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• T 3:DIESEL <br /> PRODUCT CODE 3 LIQUID SENSOR SETUP <br /> THERMAL COEFF <br /> 000450 <br /> TANK DIAMETER '. '119.75 <br /> TANK PROFILE . 4 PTS L 1 :87 STP SUMP <br /> FULL VOL : 8134 TRI-STATE (SINGLE FLOAT) <br /> 89.6 INCH VOL : 6602 CATEGORY : STP SUMP <br /> 59.9 INCH VOL : 4090 <br /> 29.9 INCH VOL : 1570 <br /> L 2:87 STP BRINE <br /> TRI-STATE (SINGLE FLOAT) <br /> FLOAT SIZE: 4,0 IN CATEGORY : OTHER SENSORS <br /> WATER WARNING 2.0 <br /> HIGH WATER LIMIT: 3.0 <br /> L 3:91 STP SUMP <br /> T 2:PREMIUM MAX OR LABEL VOL: 8134 TRI-STATE (SINGLE FLOAT) <br /> PRODUCT CODE 2 OVERFILL LIMIT 90% CATEGORY : STP SUMP <br /> THERMAL COEFF : .000700 HIGH PRODUCT 7320 <br /> TANK DIAMETER 119.75 95%10% L 4:91 STP BRINE <br /> TANK PROFILE 4 PTS DELIVERY LIMIT 7TRI-STATE (SINGLE FLOAT) <br /> FULL VOL 11777 1D% <br /> 89.8 INCH VOL 9609 813 CATEGORY : OTHER SENSORS 1 <br /> 59.9 INCH VOL 5920 LOW PRODUCT <br /> 29.9 INCH VOL 2215 LEAK ALARM LIMIT: 599 <br /> SUDDEN LOSS LIMIT: 99 L 5:DIESEL STP SUMP <br /> FLOAT SIZE: 4.0 IN. TANK TILT DDo TRI-STATE (SINGLE FLOAT) <br /> PROBE OFFSET 0,.00 CATEGORY : STP SUMP <br /> WATER WARNING 2,0 <br /> HIGH WATER LIMIT: 3.0 SIPHON MANIFOLDED TANKS L 6:DIESEL STP BRINE <br /> MAX OR LABEL VOL: 11777 T#: NONE TRI-STATE (SINGLE FLOAT) <br /> OVERFILL LIMIT 90% LINE MANIFOLDED TANKS CATEGORY : OTHER SENSORS <br /> 10599 T#: NONE <br /> HIGH PRODUCT 95% <br /> 11186 LEAK MIN PERIODIC: L 7:87 FILL SUMP <br /> DELIVERY LIMIT 177 0% TRI-STATE (SINGLE FLOAT) <br /> 1177 0 <br /> CATEGORY OTHER SENSORS <br /> LOW PRODUCT 500 LEAK MIN ANNUAL 0% <br /> LEAK ALARM LIMIT: 99 0 <br /> SUDDEN LOSS LIMIT: 99 L 8:87 FILL BRINETANK TILT 0.00 PERIODIC TEST TYPE TRI-STATE (SINGLE FLOAT) <br /> PROBE OFFSET D.00 <br /> STANDARD CATEGORY : OTHER SENSORS <br /> SIPHON MANIFOLDED TANKS ANNUAL TEST FAIL <br /> T#: NONE ALARM DISABLED L 9:91 FILL SUMP <br /> LINE MANIFOLDED TANKS PERIODIC TEST FAIL TRI-STATE (SINGLE FLOAT) <br /> T#: NONE ALARM DISABLED CATEGORY : OTHER SENSORS <br /> LEAK MIN PERIODIC: 0% GROSS TEST FAIL <br /> 0 ALARM DISABLED <br /> 1-10:91 FILL BRINE <br /> LEAK MIN ANNUAL 0% ANN TEST AVERAGING: OFF TRI-STATE (SINGLE FLOAT) <br /> 0 PER TEST AVERAGING: OFF CATEGORY : OTHER SENSORS <br /> TANK TEST NOTIFY: OFF <br /> PERIODIC TEST TYPE TNK TST SIPHON BREAKOFF LII :DIESEL FILL SUMP <br /> STANDARD <br /> TRI-STATE (SINGLE FLOAT) <br /> ANNUAL TEST FAIL DELIVERY DELAY 3 MIN CATEGORY : OTHER SENSORS <br /> ALARM DISABLED PUMP THRESHOLD : 10.004; <br /> PERIODIC_. TEST FAIL L12:DIESEL FILL BRINE <br /> ALARM DISABLED LEAK TEST METHOD TRI-STATE (SINGLE FLOAT) <br /> GROSS TEST FAIL - - - - - " - - CATEGORY : OTHER SENSORS <br /> ALARM DISABLED TEST ON DATE : ALL. TANK <br /> FEB 6. 2007 <br /> ANN TEST AVERAGING: OFF START TIME : DISABLED <br /> PER TEST AVERAGING: OFF TEST RATE :0.20 GAL/HR L13:87 ANNULAR <br /> DURATION : 2 HOURS DUAL POINT HYDROSTATIC <br /> TANK TEST NOTIFY: OFFTST EARLY STOP:DISABLED CATEGORY : ANNULAR SPACE <br /> TNK TST SIPHON BREAKOFF LEAK. TEST REPORT FORMAT <br /> DELIVERY DELAY 3 MIN NORMAL L14:91-DIESEL ANNULAR <br /> PUMP THRESHOLD 10.00% DUAL POINT HYDROSTATIC <br /> CATEGORY : ANNULAR SPACE <br />