Monitoring System Certification • • ra <br /> ��C <br /> A Results of Testing/Servicing <br /> Software Version Installed: 327.04 <br /> Com Tete the following checklist: <br /> 0 Yes rnot <br /> e audible alarm operational? <br /> Yes e visual alarm operational'? <br /> Z Yes e all sensors visuall inspected functionall tested,and confirmed operational? <br /> 0 Yes e all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> interfere with their pro er operation?❑ Yes larmsare relayed to a remote monitoring station, is all communications equipment (e.g. modem)ational? <br /> QYes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; Q Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes; ❑No. <br /> DYes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> ❑ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fillpoint(s)and operating properly9 If so,at what percent of tank capacity does the alarm trigger? 90 % <br /> ❑ Yes* 10 No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> DYes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> Z Product; Z Water. If yes,describe causes in Section E,below. <br /> D Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ❑ Yes No* Is all monitoring equipment operational per manufacturer's specifications? <br /> —;-In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> 91 LLD needs to be retested Turbine Syphon Jet was replaced. Give some time for air purging. <br /> L2 - 87 STP Brine Sensor - 420 <br /> L4 - 91 STP Brine Sensor - 420 <br /> L6 - Diesel STP Brine Sensor - 420 <br /> L8 - 87 Fill Brine Sensor - 420 <br /> L10 - 91 Fill Brine Sensor - 420 <br /> L12 - Diesel Fill Brine Sensor - 420 <br /> L16 - Vent Sump Brine Sensor - 420 <br /> L18 Dispenser 1/2 Brine Sensor - 420 <br /> L20 - Dispenser 3/4 Brine Sensor - 420 <br /> L22 - Dispenser 5/6 Brine Sensor - 420 <br /> L24 Dispenser 7/8 Brine Sensor - 420 <br /> L26 - Dispenser 9/10 Brine Sensor - 420 <br /> L28 - Dispenser 11/12 Brine Sensor - 420 <br /> UN-036-2/4 Page 2 of 5 Rev.06/04/01 <br /> w .unidocs.org <br />