Laserfiche WebLink
OUTPUT RELAY SETUP <br />FCATEGORY <br /> SEL FILL SUMP _ _ - - - - <br /> TE (SINGLE FLOAT) <br /> Y OTHER SENSORS R 1 :87 <br /> TYPE: <br /> PUMP CONTROL OUTPUT <br /> SEL FILL BRINE TAN!'. #: 1 <br /> TE (SINGLE FLOAT) <br /> : OTHER SENSORS LIQUID SENSOR ALMS <br /> L I :FUEL ALARM <br /> L17:FUEL ALARM <br /> ANNULAR L25:DTSP 9-10 PAN L19:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L21 :FUEL ALARM <br /> INT HYDROSTATIC CATEGORY DISPENSER PAN L23:FUEL ALARM <br /> CATEGORY : ANNULAR SPACE L25:FUEL ALARM <br /> L27:FUEL ALARM <br /> L ! :SENSOR OUT ALARM <br /> L26:DISP 9-10 BRINE L17:SENSOR OUT ALARM <br /> L14:91-DIESEL ANNULAR TRI-STATE (SINGLE FLOAT) L19:SENSOR OUT ALARM <br /> DUAL POINT HYDROSTATIC CATEGORY : OTHER SENSORS L21 :SENSOR OUT ALARM <br /> CATEGORY : ANNULAR SPACE L23:SENSOR OUT ALARM <br /> L25:SENSOR OUT ALARM <br /> L27:SENSOR OUT ALARM <br /> L15:VEIVT SUMP L27:DISP 11-12 PAN L 1 :SHORT ALARM <br /> TRI-STATE (SINGLE FLORT) L17:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L19:SHORT ALARM <br /> CATEGORY : OTHER SENSORS L21 :SHORT ALARM <br /> L23:SHORT ALARM <br /> L25:SHORT ALARM <br /> L28:DISP 11-12 BRINE L27:SHORT ALARM <br /> L16:VENT SUMP BRINE TRI-STATE (SINGLE FLOAT) <br /> TRI-STATE (SINGLE FLOAT) CATEGORY OTHER SENSORS SMARTSENSOR ALARMS <br /> CATEGORY : OTHER SENSORS s 1 :HIGH LIQUID ALARM <br /> ISD SITE ALARMS <br /> L17:D1SP 1-2PAN ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> CATEGORY : DISPENSER PAN ISD VP PRES FAIL <br /> ISD VP STATUS FAIL <br /> ISD SETUP WARN <br /> L18:DISP 1-2 BRINE ISD SETUP FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD SENSOR OUT FAIL <br /> CATEGORY : DISPENSER PAN ISD HOSE ALARMS <br /> PUMP SENSOR SETUP_ _ _ _ ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL <br /> L19:DISP 3-4 PAIV <br /> TRI-STATE (SINGLE FLOAT) S N UNLEADED ALL:FLOW COLLECT FOIL <br /> CATEGORY : OTHER SENSORS TANK #: 1 <br /> DISPENSE MODE: R 2:91 <br /> STANDARD TYPE: <br /> PUMP CONTROL OUTPUT <br /> L20:DISP 3-4 BRINE <br /> S 2:PREMIUM TANK #: 2 TRI-STATE (SINGLE FLOAT) TANK #: 2DISPENSE MODE: <br /> CATEGORY OTHER SENSORS STANDARD LIQUID SENSOR ALMS <br /> L 3:FUEL ALARM <br /> S 3:DIESEL L17:FUEL ALARM <br /> L21 :DISP 5-6 PAN TANK #: 3 L19:FUEL ALARM <br /> TRI-STATE [SINGLE FLOAT) DISPENSE MODE: L21 :FUEL ALARM <br /> CATEGORY : DISPENSER PAN STANDARD L23:FUEL ALARM <br /> L25:FUEL ALARM <br /> L27:FUEL ALARM <br /> L 3:SENSOR OUT ALARM <br /> L22:DISP 5-6 BRINE L17:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L19:SENSOR OUT ALARM <br /> L21 :SENSOR OUT ALARM <br /> CATEGORY : OTHER SENSORS <br /> L23:SENSOk OUT ALARM <br /> L25:SENSOR OUT ALARM <br /> L27:SENSOR OUT ALARM <br /> L23:DISF 7-8 PAN L 3:SHORT ALARM <br /> L17:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) <br /> L19:SHORT ALARM <br /> CATEGORY : DISPENSER PAN <br /> L21 :SHOkT HLAkI'1 <br /> L23:SHORT ALARM <br /> L25:SHORT ALARM <br /> L24:DISP 7-8 BRINE L27:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) SMARTSENSOR ALARMS <br /> CATEGORY : OTHER SENSORS a:HIGH LIQUID ALARM <br />