Laserfiche WebLink
SY EM SET-UP REPORT Page 3) <br /> L13:87 ANNULAR L27:D1SP 11-12 PAN <br /> DUAL POINT HYDROSTATIC TRI-STATE (SINGLE FLOAT) LIQUID SENSOR ALMS <br /> CATEGORY ANNULAR SPACE CATEGORY : DISPENSER PA14 L 3:FUEL ALARM <br /> L17:FUEL ALARM <br /> L19:FUEL ALARM <br /> L21 :FUEL ALARM <br /> L14:91-DIESEL ANNULAR L28:DTSP 11-12 BRINE L23:FUEL ALARM <br /> DUAL POINT HYDROSTATIC TRI-STATE (SINGLE FLOAT) L25:FUEL ALARM <br /> CATEGORY : ANNULAR SPACE CATEGORY : OTHER SENSORS L27:FUEL ALARM <br /> PUMP SENSOR SETUP L 3:SENSOR OUT ALARM <br /> _ _ L17:SENSOR OUT ALARM <br /> _ _ _ _ _ _ _ _ _ _ <br /> L19:SENSOR OUT ALARM <br /> L15:VENT SUMP L21 :SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) S ] :UNLEADED L23:SENSOR OUT ALARM <br /> CATEGORY OTHER SENSORS DISPENSE MODE: L25:SEN8OR OUT ALARM <br /> STANDARD L27:SENSOR OUT ALARM <br /> L 3:SHORT ALARM <br /> S 2:PREMIUM LI7:SHOR.T ALARM <br /> L16:VENT SUMP BRINE <br /> TRI-STATE (SINGLE FLOAT) TANK 2 L21 :SHORT ALARM <br /> S <br /> CATEGORY OTHER SENSORS DISPENSE <br /> L19:SHORT ALARM <br /> MODE: L23:SHORT ALARM <br /> L25:SHORT ALARM <br /> S 3:DIESEL L27:SHORT ALARM <br /> L17:DISP 1-2PAN TANK 0: 3 SMARTSENSOR ALARMS <br /> TRI-STATE (SINGLE FLOAT) DISPENSE MODE: s 4:HIGH LIQUID ALARM <br /> CATEGORY : DISPENSER PAN <br /> OUTPUT RELAY SETUPISD SITE ALARMS <br /> - - - - - - - - - - _ _ ISD GROSS PRES FAIL <br /> LlB:DISP 1-2 BRINE R 1:87 ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> TRI-STATE (SINGLE FLOAT) TYPE; <br /> FAIL <br /> CATEGORY : DISPENSER PAN PUMP CONTROL OUTPUT ISD VP STAT <br /> ISD VP STATUS FAIL <br /> TANK 0: 1 MISSING RELAY SETUP <br /> ISD SETUP FAIL <br /> L19:DISP 3-4 PAN LIQUID SENSOR ALMS ISD SENSOR OUT FAIL <br /> TRI-STATE (SINGLE FLOAT) L ( :FUEL ALARM ISD HOSE ALARMS <br /> CATEGORY : OTHER SENSORS L17:FUEL ALARM ALL:GROSS COLLECT FAIL <br /> L19:FUEL ALARM <br /> L21 :FUEL ALARM ALL:DEGRD COLLECT FAIL <br /> L23:FUEL ALARM ALL:FLOW COLLECT FAIL <br /> L20:DISP 3-4 BRINE L25:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L27:FUEL ALARM R 3:DIESEL <br /> CATEGORY : OTHER SENSORS L ] :SENSOR OUT ALARM TYPE: <br /> L17:SENSOR OUT ALARM PUMP CONTROL OUTPUT <br /> L19:SENSOR OUT ALARM TANK it: 3 <br /> L21 :SENSOR OUT ALARM <br /> L21 :DISP 5-6 PAN L23:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L25:SENSOR OUT ALARM LIQUID SENSOR ALMS <br /> CATEGORY : DISPENSER PAN L27:SENSOR OUT ALARM L 5:FUEL ALARM <br /> L 1 :SHORT ALARM L19:FUEL ALARM <br /> L17:SHORT ALARM L23:FUEL ALARM <br /> L19:SHORT ALARM L27:FUEL ALARM <br /> L22:DISP 5-6 BRINE L21 :SHORT ALARM L 5:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L23:SHORT ALARM L19:SENSOR OUT ALARM <br /> CATEGORY : OTHER SENSORS L25:SHORT ALARM L23:SENSOR OUT ALARM <br /> L27:SHORT ALARM L27:SENSOR OUT ALARM <br /> SMARTSENSOR ALARMS L 5:SHORT ALARM <br /> L19:SHORT ALARM <br /> L23:DISP 7-8 PAN s I :HIGH LIQUID ALARM <br /> L23:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) <br /> L27:SHORT ALARM <br /> CATEGORY : DISPENSER PAN ISD SITE ALARMS <br /> ISD GROSS PRES FAIL SMARTSENSOR ALARMS <br /> ISD DEGRD PRES FAIL s 6:HIGH LIQUID ALARM <br /> ISD VAPOR LEAK FAIL <br /> L24:DISP 7-8 BRINE ISD VP PRES FAIL R 4:OVERFILL <br /> TRI-STATE (SINGLE FLOAT) ISD VP STATUS FAIL TYPE: <br /> CATEGORY : OTHER SENSORS ISD SETUP WARN STANDARD <br /> ISD SETUP FAIL NORMALLY OPEN <br /> ISD SENSOR OUT FAIL <br /> TANK !<: NONE <br /> L25:DISP 9-10 PAN ISD HOSE ALARMS <br /> TRI-STATE (SINGLE FLOAT) ALL:GROSS COLLECT FAIL <br /> CATEGORY : DISPENSER PAN IN-TANK ALARMS <br /> ALL:DEGRD COLLECT FAIL ALL:OVERFILL ALARM <br /> HLL:FLOW COLLECT FAIL ALL:HIGH PRODUCT ALARM <br /> L26:DISP 9-10 BRINE R 2;91 ALL:MAX PRODUCT ALARM <br /> TRI-STATE (SINGLE FLOAT) TYPE: <br /> CATEGORY : OTHER SENSORS PUMP CONTROL OUTPUT <br /> TANK #: 2 <br /> 2006 Walton Engineering,Inc. <br />