Laserfiche WebLink
♦ SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209) 468-3420 Fax:(209)468-3433 Web:www sigoy org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Inspection date: <br /> Facility name: <br /> Facility addresfs'. n �► p yo_ UST#1 <br /> ��,."' Product <br /> Facility contact: Title: Phone: <br /> Ares(lhgr)/Ghr�t)�t G 0 CFO '7n3412'-41 / <br /> Monitoring panel: Piping system: O erfill prevention; Violations: <br /> V� I M1-RDetect 0 M2-RPre4m3-Both <br /> Pressurized O Suction O Gravity udible/visuaIAT& <br /> a <br /> T Designated era r: IZ�r(b ICC exp.date: <br /> Inspection type: <br /> N brtan , uvt�hay <br /> outine Monitoring Certification El Installation ❑Other: <br /> On site Service Technician's name: ICC exp.date: an facturer's training: VM1 P <br /> Al �l1wr 4►�b6 �� '` obO13 tri ,9iI o�311z <br /> VIOLATIONS V R <br /> # Code Section HSC=CA Health&Safety Code; CCR=CA Code of Re ulations;V=Violation; RV=Re eat Violation V <br /> 1 HSC 25284 No permit tooperate <br /> Secondary containment: (a)test not performed; (e)test report not submitted within 30 days; (f)test <br /> 2 CCR 2637 notification not provided to thqj Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test v <br /> DLL 11 <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program Monitoring&Response Plans is not current or approved <br /> by the EHD <br /> 6 CCR 2712(i) Monitoring Ian, res onse plan, and/oroperating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years, cathodic protection records for 6 Y: (Mt) <br /> years,written performance claims pertaining to release detection systems for 5 years, or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3) results \' <br /> of any visual observations; (4)results of sample analysis performed a lab or in the field; (5) logs of all 7) <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br /> results of invento readings and reconciliations <br /> 8 CCR 2643(d) Dail monitoringof suction piping re-Janua 1, 1984 not erformed M1 <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, includin sills and overfills <br /> 10 CCR 2632 c 2 Monitoring system is not present in the interstitials ace of a double walled UST M1 <br /> 11 CCR 2630(d) UST monitoring a ui ment is not installed or maintained to detect a leak at the earliest o ortunit (Mt <br /> 12 HSC 25291(b) , UST monitoring system incapable Of detecting leak from primary containment into secondary (Mt) <br /> Containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (Mt) <br /> an audible and visual alarm or stops flow of product at the dis enser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291 a 2 Secondary containment for UST system is not tight <br /> 16 CCR 2636 c 1 All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636 2 Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi M1 <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (M2) <br /> to keep the spill container empty <br /> 19 CCR 2635 b 2 Overfill nrevention s stem was overridden or failed to meet overfill requirements in this section M2) <br /> 20 CCR 2636(a) Failed to have seconds containment for piping (inclu—es conventional suction i in (M2) <br /> 21 HSC 25291 a Water in 20 containment not removed, analyzed&properly dis osed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (Mt) <br /> 22 CCR 2650 1hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of roduct was not reported to the EHD within 24 ho rs <br /> 23a CCR 2715 a Failed to inform the EHD of a change of designated o erator wi in 30 d s <br /> 23b CCR 2715(b) Designated operator did not ossess a current ICC UST ste O er or certification <br /> EHD' s ector. Received by: �i Title: <br /> �r�r d� <br /> UST INSPECTION REPORT <br /> EHD 23-02-002 REV 8/28/10 Page 1 <br />