My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:16 PM
Creation date
11/8/2018 9:53:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\116\PR0523684\COMPLIANCE INFO 2010 - 2012.PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2012
QuestysRecordDate
4/25/2018 3:57:18 PM
QuestysRecordID
3867065
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL fDILL CONTAINER TE,* REPORT <br /> TEST DATE: December 28, 2009 <br /> A1. FACILITY A2. OWNER <br /> Name Fast Lane Lathrop Name Christina Gill <br /> Address 116 E.Roth Road,Lathrop, CA 95330 Address 111 Healdsburg Avenue, Healdsburg,CA 95448 <br /> Phone# 707-431-0541 Phone# 707-431-0541 <br /> Contact Christina Gill Contact Christina Gill <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E.Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified December 22, 2009 Lic# 617238 A,B,Haz <br /> Inspector Michelle Henry Contact Richard Walton <br /> Phone# 209-468-3439 Phone# 916-825-3203 <br /> K. SPILL CONTAINER TEST RESULTS <br /> Measuring Equipment Used: Caldwell System 2001 /Walton Engineering (Level Change Indicator) <br /> Tank Number 1 2 3 <br /> Product contained Gasoline-87 Gasoline-91 Diesel <br /> Spill container capacity (US gallons) 5 5 5 <br /> Spill container manufacturer OPW OPW OPW <br /> Spill container depth (inches) 15.50 16.00 15.50 <br /> Is the spill container located in a sump? Yes Yes Yes <br /> Does sump have a liquid sensor installed? Yes Yes Yes <br /> Condition of spill container prior to testing Dry Dry Dry <br /> Portion of spill container tested Entire Entire Entire <br /> Depth of water level from bottom (Inches) 13.50 14.50 13.50 <br /> Wait time for water level to stabilize (hr:min) 0:05 0:05 0:05 <br /> Test start time 10:35 10:33 11:30 <br /> Test end time 11:05 11:03 [12:00 <br /> Test duration (hr:min) 0:30 0:30 0:30 <br /> Change in water level it 0.000 inches) 0.000 0.000 0.000 <br /> Pass/Fail threshold (0.005 inches I Y:Hr.) 0.005 0.005 0.005 <br /> TEST RESULT PASS PASS PASS <br /> L. COMMENTS: <br /> The MSC test water was left on site in owner supplied drum. <br /> WA1.TON --- <br /> Signature: -C C7 NGINVenikc, INC.; <br /> Technician: Gerardo Guzman/8353945242481-UT Date: Decernber28, 2009 <br /> ©2006 Walton Engineenng,Inc. <br />
The URL can be used to link to this page