Laserfiche WebLink
0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.ora/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> FNameadllty: Fast Lane Central Valley LLC n dire a: 116 East Roth Road, Lathrop IDnaateection Jul 30, 2012 <br /> Fadlky Title: Operations Manager IV-326-0369 <br /> Conpct Hardeep Gill <br /> Inspection XRoufine XMonilonng System certification ❑Installation ❑Complaint-IDI. XOdw finish truck side 6/20 <br /> Type: <br /> (Authonty HSC 25289) Anes Mabalot store manager <br /> Consentfur. Xlnspection XSampling XPhotos Grantedby- g Title: <br /> Monitoring Veeder-Root TLS-350 Piping XPreswnzed OSuchon DGravdy, pO�Overfill on: 0Mechankxl XAudfbleMsual <br /> Panel: SYst�: <br /> UST auto 1 2 3 truck 4 5 <br /> -------------- -------------- -------------------------- ------------ - <br /> ---Product--- - --side -_-- --91-octane-- ----DSL---- 87-octane side DSL DSL <br /> Designated lcc Exp. 1212/1112 Violations: ❑M1-Rda w Detection ❑M2-Release Prevention I7 M3-Both <br /> Operator. B.Dunahay/A.Milburn Date: <br /> On Site S70a Alvin Milburn IIie� 111212 Maanufa cturer' s VR 061913 VMI 032614 <br /> Technida <br /> VIOLATIONS <br /> HSC=California Heath and Cale'2 CCR=Catfomie Code d Regulators <br /> # Cl C2 M Code Section Cl=Class 1 violation;C2=Gass vidation;M=Mina violation <br /> File Review <br /> 101 X HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) al plaNslt'map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Second containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 X HSC 25291(f) Annual line leak detector test not performed (Mt) <br /> 111 X HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed iit positive shutdown or fail safe not present (M11 <br /> 113 CCR 2715(a) Failed to intone the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak deterdion(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 120 HSC 25298(c) Permit to dose UST system not obtained <br /> On Site Records <br /> Maintenance It monitoring records not maintained 3 years,cathodic protection records for 6 h years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 X CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results; 6 results of invento readings and reconciliations <br /> 202 X CCR 2712(1) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 X CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not refled to the EHD within 24 hours <br /> Inspector Received Ely: -yr. rte: <br /> —91 <br /> Thuy Tran (209) 468-8257 �1 <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />