My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
INSTALL_2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 4:22:05 PM
Creation date
11/8/2018 9:53:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2006
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\116\PR0523684\INSTALL 2006.PDF
QuestysFileName
INSTALL 2006
QuestysRecordDate
4/24/2018 10:24:48 PM
QuestysRecordID
3865777
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENVIRONMENTAL HEALTAEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> i. Donna K.Heran,R.E.H.S. Unit Supervisors <br /> Director <br /> 304 East Weber Avenue, Third Floor carr sorgman,R.E.H.S. <br /> Al Olsen,R.E.H.S. Stockton, California 95202-2708 Mike Huggins,R.E.H.S.,R.D.I. <br /> Douglas W.Wilson,R.E.H.S. <br /> • �q, arc • Program Manager <br /> Laurie A.Cotulla,R.E.H.S. Telephone: (209) 468-3420 Margaret Lagorio,R.E.H.S. <br /> t1Foa <br /> Manager Program Fax: (209)464-0138 Robert McClellon,R.E.H.S. <br /> g g Mark Barcellos,R.E.H.S. <br /> May 26, 2005 <br /> Fillner Construction <br /> 4470 Yankee Hill Rd., Ste. 200 <br /> Rocklin CA 95667 <br /> Re: Fast Lane Central Valley, LLC, 316 E. Roth Rd. Lathrop CA Apll 1 0'(' d 20 20 <br /> Your application for permit to install a new underground storage tank system at the above location has <br /> been approved with the following conditions: <br /> 1. Contact the fire department and the San Joaquin Valley Air Pollution Control District for <br /> applicable permits. <br /> 2. The contractor shall be licensed by the Contractors Licensing Board. <br /> 3. At least one person who holds the International Code Council (ICC) UST Installer/Retrotitter <br /> certification must be onsite when work is performed. <br /> 4. Any changes shall be submitted to the Environmental Health Department (EHD) for approval prior <br /> to commencing work. All new submittals supercede the previous ones. <br /> 5. All piping, fittings, sumps, under-dispenser containment and tanks must be certified by an <br /> independent testing organization and labeled as required by the organization. (UL, ULC,ANSI, <br /> API, ASTM ect...See Title 23 Chapter 16 Table B for complete list) <br /> 6. All monitoring systems shall be listed on the LG113-16. <br /> 7. All testing shall be in compliance with manufacturer's instructions, section 2635 and section 2636 <br /> of California Code of Regulations (CCR) <br /> 8. Recommend installing automatic pump shutdown, which will, satisfy CCR 26350. <br /> 9. All piping must slope to a containment sump with an audible/visual alarm. <br /> 10. All connections (valve stems) from the vacuum on the piping to the vacuum source must be turned <br /> down in the piping sump. <br /> 11. All tank top openings, that are connected to the primary space of the UST must have secondary <br /> containment, audible/visual alarm and be vapor tight or terminate at grade. <br /> 12. Sumps and under dispenser containment must be constructed in a manner to prevent vapors from <br /> entering the backfill. <br /> 13. All secondary containment must be constructed to prevent water intrusion. <br /> 14. The secondary containment system must be continuously monitored as required under California <br /> Health& Safety Code (HSC) 25290.1 <br /> 15. Overfill prevention shall satisfy CCR 2635(b)(2)(B). <br /> 16. Underground storage tanks are to be anchored per the permit application. <br /> 17. The tank owner must submit the owner statement and name/ICC certification information for this <br /> facility's, "California UST System Operator" (Designated Operator) prior to the final inspection. <br /> 18. A "Certificate of Compliance for Underground Storage Tank Installation Form C" shall be <br /> submitted by the owner or the owners' agent [pursuant to California Code of Regulation (CCR) <br /> 2635(d)] before this project will be considered complete by SJCEHD. <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.