My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
INSTALL_2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 4:22:05 PM
Creation date
11/8/2018 9:53:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2006
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\116\PR0523684\INSTALL 2006.PDF
QuestysFileName
INSTALL 2006
QuestysRecordDate
4/24/2018 10:24:48 PM
QuestysRecordID
3865777
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Results of Evaluation Using <br /> "European Standard prEN 13160-2, "Leak Detection <br /> Systems — Part 2: Pressure and vacuum system" <br /> May 2003 <br /> This form tells whether the vacuum interstitial testing method described below complies with the <br /> performance requirements of the US federal underground storage tank regulations. The <br /> evaluation was conducted by an independent testing organization for the manufacturer according <br /> to the procedures described in "European Standard prEN 13160-2, "Leak Detection Systems— <br /> Part 2: Pressure and vacuum system", May 2003. This protocol was adopted by the National <br /> Work Group on Leak Detection Evaluations and may be used for the evaluation of vacuum based <br /> systems that monitor the interstice of either double-wall tanks or pipelines. <br /> Tank owners using this leak detection system should keep this form on file to prove compliance with the <br /> federal regulations. Tank owners should check with State and local agencies to make sure this form <br /> satisfies their requirements. <br /> Method Description <br /> Name Veeder-Root Vacuum Interstitial Monitoring System <br /> Version Secondary Containment Leak Detection(SCLD) System <br /> ( Vendor Veeder-Root <br /> 125 Powder Forest Drive, P.O. Box 2003 <br /> (street address) <br /> Simsbury CT 06070 (860) 651-2700 <br /> (city) (state) (zip) (phone) <br /> Evaluation Results <br /> Based on the results above this method(X) does ( ) does not meet the performance standards <br /> established by the European Committee for Standardization as specified in "European Standard <br /> prEN 13160-2, "Leak Detection Systems—Part 2: Pressure and vacuum system", May 2003 <br /> Pipeline and Reservoir Characteristics <br /> This protocol does not specify line or tank size based on the test conditions. It does not function <br /> as a conventional leak detector, but rather as a system to prevent the loss of product to the <br /> environment in as fail safe manner as possible. The protocol specifies that the interstitial space <br /> for a tank must be less than or equal to 8 cubic meters (2114 gal). The interstitial space for a line <br /> must be less than or equal to 20 cubic meters (2642 gal). There are no other size or design <br /> characteristic requirements. <br /> MSR 01-04-A 6 DRAFT COPY <br />
The URL can be used to link to this page