My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0505735
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 3:29:34 PM
Creation date
11/8/2018 9:53:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0505735
PE
2361
FACILITY_ID
FA0006972
FACILITY_NAME
TSI TRANS SYSTEM INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231-9774
APN
19332008
CURRENT_STATUS
01
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\ROTH\707\PR0505735\COMPLIANCE INFORMATION 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFORMATION 2008 - 2015
QuestysRecordDate
6/29/2018 3:29:31 PM
QuestysRecordID
3930717
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � • • <br /> Piping information continued- <br /> check Code <br /> Section <br /> 252901(c)1 Piping compatible with material intended to be stored. <br /> 25290.2 c 1 <br /> 23C R Design and construction of piping approved by independent testing organization(e.g.UL). rte <br /> 2631 <br /> Piyin�, includingvent lines sloped toward tanks with minimum 1/4 inch slo a er 1 foot of run. <br /> 25290.1(k) �T l-''TL t��. <br /> 25290.20&0) Va or recovery,fill riser,and vent line piping are secondarily contained. <br /> G. OVERSPILL/OVERFILL PREVENTION: <br /> sox Code <br /> Section <br /> 23 CCR Overspill containment having m'nimum capacity of 5 gall ns provided at each tank fill location. <br /> 2635(b) Manufacturer Model <br /> Approved overfdi prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or. <br /> triggering an audible visual alarm <br /> Restrict delivery of flow to the tank at least 30 minutes before the tank overfills,provided the <br /> restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an audible <br /> 23 CCR alarm at least five minutes before the tank overfills <br /> 2635(bx2) _ <br /> . Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to produc due to overfilling. <br /> Manufacturer Model <br /> CORROSION PROTECTION: <br /> CBo k Code <br /> Section <br /> Fiberglass re forced plastic(FRP). <br /> Piping corrosion protection: i cathodic protection or impressed current <br /> 23 CCR Steel isolated from contact with backfill <br /> 2636(b) fj <br /> FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: Sacrificial Anode <br /> ❑ <br /> 23 CCR Steel tank with field installed cathodic protection or impressed <br /> 2635(x)(2) current <br /> ❑ I I Tie-downs,when used constructed of non-corrosive material or coated steel. <br /> Revised 8/3/07 7 <br />