My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1987-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SHAW
>
1113
>
2300 - Underground Storage Tank Program
>
PR0231728
>
COMPLIANCE INFO 1987-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 2:54:34 PM
Creation date
11/8/2018 9:53:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2015
RECORD_ID
PR0231728
PE
2361
FACILITY_ID
FA0003565
FACILITY_NAME
UNIVERSAL SWEEPINGS SERVICES
STREET_NUMBER
1113
STREET_NAME
SHAW
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
14327042
CURRENT_STATUS
02
SITE_LOCATION
1113 SHAW RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\S\SHAW\1113\PR0231728\COMPLIANCE INFO 1987-2015.PDF
QuestysFileName
COMPLIANCE INFO 1987-2015
QuestysRecordDate
5/31/2017 3:41:00 PM
QuestysRecordID
3403671
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OIL EQUIPMENT SERE • STATE LICENSE No.323417 <br /> CLASSIFICATION. A-RAZ.,C611140 <br /> Division of Keith A. Tallia, Inc. STATE ENVIRONMENTAL ASSESSOR No.01781 <br /> Telephone: (209)754-1809 <br /> Fax: (209)754-5726 <br /> Poet Office Box 950 <br /> 750 Industrial Way <br /> SAN ANDREAS,CALIFORNIA 95249 <br /> MONITORING SYSTEM CERTIFICATION <br /> This fonn must he used to document testing :111d servicing of monitoring equipment. If more than One <br /> monitoring system control panel is installed at the fatality, a separate certification or report must be pretfared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be <br /> provided to the tank system owner/operator. The owner/operator must submit a copy of this fonn to the local <br /> agency regulating UST systems within 30 days of test (late. Instructions are printed on the back of this page. <br /> A. General Information <br /> FacilityName: Bob Cat Central -__ Bldg.No.: <br /> Site Address: 1113 Shaw Road City: Stockton .__ Zip: <br /> Facility Contact Person: Dori FranZia _ Contact Phone Na: ( 209. <br /> Make/Model of Monitoring System: INCON TS 100012 Date of Testing/Setvicing: _ 9/8 X00 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank ID: T 1 Req. Gas Tank ID: T 2 Diesel <br /> 0 In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> W Annular Space or Vault Sensor. Model: TSP-I1T.S CX Annular Space'or Vault Sensor. Model: TSP ETS <br /> W Piping SumpiTrench Sensor(s). Model: TSP-11T.S _ <br /> C;t Piping Sump/I'rench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> 0 Mechanical Line Leak Detector. Model: 0 Mechanical Line Leak Detector. Model: <br /> 0 Electronic Line Leak Detector. Model-CampCJMi 1 1 er 2l• Ck Electronic Line Leak Detector. Model lipc * <br /> W Tank Overfill/High-Level Sensor. Modcl:61 S(1 Dro Tube IX Tank Overfill/High-Level Sensor. Model <br /> O Dispenser Containment Sensor(s). Model: Cl Dispenser Containment Sensor(s). Model: _ <br /> M Shear Valve(s). *LS300 CX Shear Valve(s). <br /> Cl *LS300 <br /> Dispenser Containment Floar(s)and Chain(s). 0 Dispenser Containment Float(s)and Chain(s). <br /> 0 Other(specify ui ment type and model in Section E on Page 2). 0 Other(specify equipment t e and model in Section E on Page 2). <br /> Tank ID: Wactp Oil Tank ID: <br /> 0 In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> 52 Annular Space or Vault Sensor. Model:P Om ter* O Annular Space or Vault Sensor. Model: <br /> 0 Piping SumptTrench Sensor(s). Modci: *Mod 2-9-- 0 0 Piping Sump/Trench Senson s). Model: <br /> Cl Fit l Sump Sensor(s). Model: Type-_TX.—. ❑ Fill Sump Sensor(s). Model: _ <br /> 11 Mechanical Line Leak Detector. Model: O Mechanical Line Leak Detector. Model: <br /> 0 Electronic Line Leak Detector. Model: _ 0 Electronic Line Leak Detector. Model: _ <br /> 0 Tank Overfill/High-Level Sensor. Model:VPnl Ra 1 1 ohjC 0 Tank Overfill/High-Level Sensor. Model: <br /> 0 Dispenser Containment Sensor(s). Model: _ ❑ Dispenser Containment Sensor(s). Model: <br /> 8 0 Shear Valvc(s). U Shear Valve(s). <br /> Cl Dispenser Containment Iloags)and Chain(s). 0 Dispenser Containment Floa1(s)and Cham(s). <br /> ❑ Other(specify equipment t e and model in Section E on Page 21, 0 Other(s ecifv equipment x and model in Section on Page 2). <br /> C- Certification - I certify that the equipment identified in (his document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. .Attached to this Certification is information (e.g. manufacturers' checklists) necessary to <br /> verify that this information is correct and a Site Plan sholcing the layout of intiouoring equipment. For a ry equipment <br /> eipable of ocn eratin,� such reports. I ha%e also im:ichrd :1 rnp) of the (rd eck atf that apphy: 0 system s t-up report: <br /> ❑ Alarm It ssttory repot. <br /> 7-ectmician Name (print): James g Ileslceth- - - Cert./Lie. No.: 0(;6�--__-_ Signaune: <br /> Teshu g Com any Namc• ///"`"""" ' <br /> S p Oil _Equipment Service Phone No.: � 20 754-1 808 <br />