My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1987-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SHAW
>
1113
>
2300 - Underground Storage Tank Program
>
PR0231728
>
COMPLIANCE INFO 1987-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 2:54:34 PM
Creation date
11/8/2018 9:53:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2015
RECORD_ID
PR0231728
PE
2361
FACILITY_ID
FA0003565
FACILITY_NAME
UNIVERSAL SWEEPINGS SERVICES
STREET_NUMBER
1113
STREET_NAME
SHAW
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
14327042
CURRENT_STATUS
02
SITE_LOCATION
1113 SHAW RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\S\SHAW\1113\PR0231728\COMPLIANCE INFO 1987-2015.PDF
QuestysFileName
COMPLIANCE INFO 1987-2015
QuestysRecordDate
5/31/2017 3:41:00 PM
QuestysRecordID
3403671
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CAMPO <br /> mLu <br /> LSNO-M ELECTRONIC AUTOMATIC LINE LEAK DETECTOR <br /> ALARMS WITHIN SECONDS WHEN PRODUCT LINE LEAK OCCURS <br /> CAMpo <br /> #t F <br /> LINE LAK DETECTOR rrM"^a,a.ue�y � <br /> 89 ^''dle q� <br /> , ryh TOff[T •q obey 'S <br /> PW Y1111p AVL L1n�M�yC1 j <br /> m" <br /> FEATURES: <br /> • THIRD PARTY TESTED- In accordance with the EPA requirements, a nationally recognized testing labo atory <br /> conducted tests which thoroughly tested the LS300-120 under real world conditions. <br /> • LEAK TEST-A leak test is performed each time the submersible pump is shutdown.If a leak is detected an ilarm <br /> is activated with audio,visual and remote signaling capabilities. <br /> • FLEXIBILITY - The LS300-120 test parameters are field adjustable to allow compensation for a particular site's <br /> characteristics.Thus avoiding the false alarms that are so familiar with mechanical line leak detectors. <br /> • FALSE ALARM-If a false alarm is sounded due to a faulty valve or debris in the piping system the LS300-12 will <br /> not disrupt product sales by preventing continued operation of the system. <br /> •AUTO CLEARING-Automatically resets alarm,if subsequent test shows no leak.Avoids the need for the op-rator <br /> to manually reset alarms due to transient conditions,such as an improper seating of the turbine pump check va ve. <br /> •EASY TO INSTALL-Detectorcan be mounted on dispensertop,utilizes existing AC power and a transducers Irews <br /> into existng port of the dispenser's fire valve.No special tools or training required. <br /> OPERATION: <br /> The Model LS300-120 is designed to perform a leak test at the end of each pumping cycle by monitoring the pixiduct <br /> line pressure decay time immediately following the pump shut down.The test compares the expected line pressure decay <br /> with the actual pressure decay.The leak test is initiated when the line pressure signaled to the controller by the transducer <br /> drops below the high threshold,the test lasts 10 to 150 seconds (selectable).If the line pressure decays to below the low <br /> pressure threshold prior to the conclusion of the test period,a leak condition is indicated and the alarm is activatod.An <br /> on-board relay output is activated with the alarm for the purpose of remote signaling and/or submersible pump <br /> deactivation. If a subsequent test results in a no leak condition then the alarm will self cancel .An alarm may a so be <br /> cancelled by depressing the Test/Reset button.An on-demand self test function provides verification of the coni per's <br /> operating status.Front panel indicators give the current status of the LS300-120 at every point of its'operational ycle. <br /> CAMPO/ MILLER Post Office Box 1809,Porerville;CA 93258-1809,(209)781-6862, FAX(209)781-7304 <br /> Rev B 7191 <br />
The URL can be used to link to this page
Your browser does not support the video tag.