Laserfiche WebLink
LIQUID SENSOR SETUP <br />OUTPUT RELAY SETUP <br />- - - - - - - - - - - - <br />- - - - - - - - - - - - <br />R 3:87 STP <br />TYPE: <br />L IDSL ANNULAR <br />R 1:DSL STP <br />STANDARD <br />TRI-STATE (SINGLE FLOAT) <br />TYPE:' <br />NORMALLY CLOSED <br />CATEGORY : ANNULAR SPACE <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 3 <br />TANK #: 1 <br />L 2:DSL STP SUMP <br />IN -TANK ALARMS <br />• <br />TRI-STATE (SINGLE FLOAT) <br />T 3:HIGH WATER ALARM <br />CATEGORY : STP SUMP <br />IN -TANK ALARMS <br />T 3:LOW PRODUCT ALARM <br />T I:HIGH WATER ALARM <br />T 1:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 3:91 FILL SUMP <br />L 7:FUEL ALARM <br />TRI-STATE (SINGLE FLOAT) <br />LIQUID SENSOR ALMS <br />L 9:FUEL ALARM <br />CATEGORY : PIPING SUMP <br />L 2:FUEL ALARM <br />L10:FUEL ALARM <br />L12:FUEL ALARM <br />LII:FUEL ALARM <br />L14:FUEL ALARM <br />L12:FUEL ALARM <br />L 4:91 STP SUMP <br />L 2:SENSOR OUT ALARM <br />L13:FUEL ALARM <br />TRI-STATE (SINGLE FLOAT) <br />L12:SENSOR OUT ALARM <br />L14:FUEL ALARM <br />CATEGORY : STP SUMP <br />L14:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />L 9:SENSOR OUT ALARM <br />L12:SHORT ALARM <br />L10:SENSOR OUT ALARM <br />L 5:87 ANNULAR <br />L14:SHORT ALARM <br />Lll:SENSOR OUT ALARM <br />TRI-STATE (SINGLE FLOAT) <br />L12:SENSOR OUT ALARM <br />CATEGORY : ANNULAR SPACE <br />R 2:91 STP <br />L13:SENSOR OUT ALARM <br />TYPE: <br />L14:SENSOR OUT ALARM <br />STANDARD <br />L 7:SHORT ALARM <br />NORMALLY CLOSED <br />L 9:SHORT ALARM <br />L 6:87 FILL SUMP <br />L10:SHORT ALARM <br />TRI-STATE (SINGLE FLOAT) <br />TANK #: 2 <br />LII:SHORT ALARM <br />CATEGORY : PIPING SUMP <br />L12:SHORT ALARM <br />L13:SHORT ALARM <br />IN -TANK ALARMS <br />L14:SHORT ALARM <br />L 7:Q7 STP SUMP <br />T 2:HIGH WATER ALARM <br />TRI-STATE (SINGLE FLOAT) <br />T 2:LOW PRODUCT ALARM <br />ISD SITE ALARMS <br />CATEGORY : STP SUMP <br />ISD GROSS PRES FAIL <br />LIQUID SENSOR ALMS <br />ISD DEGRD PRES FAIL <br />L 4:FUEL ALARM <br />ISD VAPOR LEAK FAIL <br />L 9:PUMP 1-2 <br />L 9:FUEL ALARM <br />ISD VP PRES FAIL <br />TRI-STATE (SINGLE FLOAT) <br />LIO:FUEL ALARM <br />ISD VP STATUS FAIL <br />CATEGORY : DISPENSER PAN <br />L11:FUEL ALARM <br />• <br />L12:FUEL ALARM <br />ISD HOSE ALARMS <br />L13:FUEL ALARM <br />ALL:FLOW COLLECT FAIL <br />L14:FUEL ALARM <br />L10:PUMP 3-4 <br />L 4:SENSOR OUT ALARM <br />+ R 4:OVER-FILL ALARM <br />TRI-STATE (SINGLE FLOAT) <br />L 9:SENSOR OUT ALARM <br />TYPE: <br />CATEGORY : DISPENSER PAN <br />L10:SENSOR OUT ALARM <br />• 4r STANDARD <br />L11:SENSOR OUT ALARM <br />NORMALLY OPEN <br />L12:SENSOR OUT ALARM <br />L13*ENSOR OUT ALARM <br />TANK #: NONE <br />LII:PUMP 5-6 <br />L14:SENSOR OUT ALARM <br />TRI-STATE (SINGLE FLOAT) <br />L 4:SHORT ALARM <br />CATEGORY : DISPENSER PAN <br />L 9:SHORT ALARM <br />IN -TANK ALARMS <br />L10:SHORT ALARM <br />ALL:OVERFILL ALARM <br />Lll:SHORT ALARM <br />ALL:HIGH PRODUCT ALARM <br />L12:SHORT ALARM <br />L12:PUMP 7-8 <br />L13:SHORT ALARM <br />TRI-STATE (SINGLE FLOAT) <br />L14:SHORT ALARM <br />CATEGORY : DISPENSER PAN <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />L13:PUMP 9-10 <br />ISD VAPOR LEAK FAIL <br />TRI-STATE (SINGLE FLOAT) <br />ISD VP PRES FAIL <br />CATEGORY : DISPENSER PAN <br />ISD VP STATUS FAIL <br />ISD HOSE ALARMS <br />ALL:FLOW COLLECT FAIL <br />L14:PUMP 11-12 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L16:NONE <br />• <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />