My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - PRESENT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/8/2018 9:54:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\HWY 26\18754\PR0507164\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
1/17/2017 11:13:57 PM
QuestysRecordID
3313957
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />KtUEIVE® <br />0 JUL') 8 <br />Appendix VI 2U10 <br />MONITORING SYSTEM CERTIFICATION ENVIRONMENTAL <br />For Use By All Jurisdictions Within the State of Califomia PERM <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of RegUl� r$VI EES rN <br />This toren must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date <br />General Information <br />Facility Name: ORLANDOS MARKET <br />Bldg. No.: <br />Site Address: 18754 LINDEN RD HWY 26 City: LINDEN Zip: 95236 <br />Facility Contact Person: SAMMY Contact Phone No.: (209) 887-1100 <br />Make/Model of Monitoring System: V EEDER ROOT TLS 350 <br />B. Inventory of Equipment Tested/Certified <br />., r..._..e ... :..w�..�.e s.. e ni <br />Date of Tesfing/Servicing: 7112/2016 <br />-If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the racinry. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Ed Stearns <br />Certification No.: A31048 <br />Testing Company Name: AFFORDA-TEST <br />Testing Company Address: 416 2n° STREET GALT, CA 95632 <br />Signature: C<f _�--J%------ <br />License No: <br />Phone No. (209) 744-0113 <br />Date of Testing/Servicing: 7/1216 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />Tank ID: 87 <br />Tank Size: <br />Tank ID: 91 Tank Size: <br />® In -Tank Gauging Probe. <br />Model: <br />MAG -1 <br />® In -Tank Gauging Probe. <br />Model: MAG -1 <br />® Annular Space or Vault Sensor. <br />Model: <br />420 <br />® Annular Space or Vault Sensor. <br />Model: 420 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />® Mechanical Line Leak Detector. <br />Model: <br />99 LD 2000 <br />® Mechanical Line Leak Detector. <br />Model: 99 LD 2000 <br />❑Electronic Line Leak Detector. <br />Model: <br />ElElectronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />90% <br />® Tank Overfill / High -Level Sensor. <br />Model: 90% <br />❑ Other (specify equipment type and model <br />in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: DIE <br />Tank Size: <br />Tank ID: <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: <br />MAG -1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: <br />420 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: <br />99 LD 2000 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Omer (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model : 208 <br />® Shear Velvets). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Velve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chairi <br />DispenserlD: 9-10 <br />DispenserlD: 11-12 <br />® Dispenser Containment <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />IR Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />-If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the racinry. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Ed Stearns <br />Certification No.: A31048 <br />Testing Company Name: AFFORDA-TEST <br />Testing Company Address: 416 2n° STREET GALT, CA 95632 <br />Signature: C<f _�--J%------ <br />License No: <br />Phone No. (209) 744-0113 <br />Date of Testing/Servicing: 7/1216 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.