My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2003 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2003 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:10:35 PM
Creation date
11/8/2018 9:54:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2006
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2003 - 2006.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2006
QuestysRecordDate
2/27/2018 6:46:39 PM
QuestysRecordID
3808828
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
302
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POMECMPW MOLT RTJ <br /> SPILL CONTAINMENT HOLES <br /> Features Riser Spacing <br /> Raintight Service-Buna-N gaskets on the <br /> manhole and spill bucket mounting rings help <• , <br /> prevent contamination of the sump area from <br /> surface water intrusion. b ' N9P°�dT�l4 <br /> •Highway 20 Load Rating-The rugged . :°. s>> a'aa;•<$:::; <br /> diamond plate steel manhole covers, as <br /> well as the cast iron (RT)or aluminum (SC) <br /> spill container covers meet H2O Load Rating <br /> requirements. <br /> ®Spill Container and Manhole Positive I.D. <br /> System-Special recesses cast into spill <br /> container covers and machined into manhole <br /> lids allow"Peel &Stick"tags to be attached <br /> to the lids. Matching bucket tags can be <br /> affixed to the inside of the spill container <br /> to prevent covers from getting switched. <br /> CARB Certified-311 Series Approval Letter <br /> #93-25, 511 and 611 Series Approval Letter <br /> #92-12. <br /> ♦FillNapor Ports-Configurations are <br /> available to accommodate a single fill riser, <br /> dual ports for both a fill and vapor riser, and <br /> triple and quad ports for multiple fill and ♦Fastener Options-Two types of Custom Multi-Port Manholes- <br /> vapor risers. Vapor ports can be supplied fasteners are available to secure Contact your POMECO/OPW <br /> with or without containment buckets. the manhole lid and monitoring port representative. <br /> Port Configurations-Standard port to mounting rings. Standard are ♦Powder Coated Rings& Covers- <br /> locations match the popular riser spacings /is -18 hex head bolts. Optional are Available upon request. <br /> (12", 14", 16"or 24")and bung configurations POMECO/OPW Roto-Lock Fasteners. p q <br /> on underground storage tanks. Custom port The POMECO/OPW Roto-Lock <br /> locations are easily accommodated. system enables a secure,watertight <br /> connection without the need to <br /> ♦Monitoring Ports-Bolt-down,gasketed locate threaded bolt holes on <br /> monitoring ports can be incorporated into the the mounting ring. <br /> manhole cover to provide observation access <br /> to the sump without removing the entire <br /> cover. Standard port diameter is 5"(13 cm) <br /> with larger ports available upon request. <br /> Manhole Cover Sizes-Standard bolt-down <br /> manhole cover a d'lametersf <br /> 0 30 76 cm <br /> 37 (94 cm), 42 (107 cm), and 48 (122 cm) �. <br /> allow ample access to the sump area. <br /> Provision for a X'-13 lifting eyebolt is <br /> provided on 42"and 48"models. Heavy-duty <br /> reinforced lid options are also available. <br /> ®Spill Container Cover Options-Standard r h, <br /> spill container options include the patented ` `h . <br /> POMECO/OPW dam and groove Raintightw -, <br /> (RT)design and the watertight Sealable ;,� 4 <br /> 'r Cover(SC) "plumber's plug"design. The <br /> Raintight cover features a finger-grip lifting _ <br /> facility and an integral seal.The sealable <br /> cover features a cam-operated mechanism <br /> that expands the seal against the vertical <br /> wall of the mounting ring. Both of these <br /> water-shedding covers are protected by <br /> raised mounting rings.A below-grade (BG) <br /> option is available which provides watertight s <br /> ' underground containment vessels while <br /> " maintaining a non-waterlight flush manhole <br /> cover surface. _ to • , <br /> i* <br /> t: <br /> North America Toll Free—TELEPHONE:(800)422-2525 Fax:(800)421-3297 Email:domesticsales Ropw-fc com IR <br /> ® � � International—TELEPHONE:(513)870-3315 or(513)870-3261 *Fax:(513)870-3157*Email:intlsales@opw-fc.com <br /> www.opw-fc.com X <br /> a ®vow 'comraur ©Copyright 2003,OPw Fueling Components P.O.Box 405003 Cincinnati,OH 45240-5003 Printed in USA 3103 <br />
The URL can be used to link to this page
Your browser does not support the video tag.