My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:19:49 PM
Creation date
11/8/2018 9:54:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
2/27/2018 5:13:36 PM
QuestysRecordID
3808429
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AFFORD -TET 416 2nd Street Galt CA 9563 LINE & LEAK DETECTOR <br /> (209) 744-0112 FAX (209) 744-011 TEST REPORT <br /> CONTRACTOR/ENGINEER TEST DATE ' ' <br /> SITE NAME ��>C <br /> ADDRESS <br /> Repair/Construction 71 LOCATION SKETCH <br /> Show North <br /> Compliance <br /> Insurance — — <br /> Escrow <br /> Make &Type of Pump or 71P <br /> enser l <br /> �L� <br /> Cover Over Lines <br /> � F <br /> Approx Burial Depth A A- <br /> 3 L � 91 <br /> Weat r <br /> 0 <br /> Pressur SUCtIOn SHOW STREETS, BLDGS,TANKS, ISLANDS,PIPING(IF KNOWN), PUMPS OR DISPENSERS <br /> LEAK DETECTOR FTA LEAK DETECTOR TEST INFORMATION Calibrate <br /> 10 PSI <br /> Opening I Element <br /> LD Serial Time In Test Leak Holding Pass/ <br /> KEY TYPES No/Product Key Number Resiliency Seconds Rate ML/Min PSI Metering PSI Fail <br /> A LD 2000 <br /> B LD 2000 E <br /> C FXI V <br /> D FXI DV <br /> E STPMLD <br /> F STPMLD - D <br /> G STPMLD- E <br /> H STPMLD - D/E Notes: <br /> CONTRACTOR LINE TEST RESULTS <br /> CERTIFICATION Tests were made on the line systems as noted in accordance with test procedures <br /> Technician:Zane A. Nimm--o- prescribed for as detailed on the test chart on Side 2 of this form with results as follows: <br /> LINE IDENTIFICATION NET VOLUME CHANGE PER HOUR <br /> PETROTITE CERT1f, T ASS FAIL / INCONCLUSIVE —, Cu f O <br /> CCA0202112304R <br /> OTTL Lic#04-1676 c:c-T PASS / FAIL / INCONCLUSIVEVOOC� <br /> Trainee: __ <br /> G i PASS / AIL / INCONCLUSIVE f� ; <br /> PASS / FAIL / INCONCLUSIVE <br /> EQUIPMENT:PETRO TITE LINE TESTER <br />
The URL can be used to link to this page
Your browser does not support the video tag.