My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:19:49 PM
Creation date
11/8/2018 9:54:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
2/27/2018 5:13:36 PM
QuestysRecordID
3808429
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br />Software Version Installed: ( n . 0 <br />nolete the follnwinn rhprkne*- <br />�1 Yes <br />❑ No* <br />Is the audible alarm operational? <br />Is the visual alarm op%rational? <br />Were all sensors visu lly inspected, functionally tested, and confirmed operational? <br />® Yes <br />❑ No* <br />® Yes <br />❑ No* <br />91 Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and position ed so that other equipment will not interfere with their proper <br />operation? <br />If alarms are relayed ~'o a remote monitoring station, is all communications equipment (e.g.. modem) operational? <br />i <br />❑ Yes <br />❑ No* <br />N/A <br />® Yes <br />❑ No* <br />❑ N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, <br />fails to operate, or is! electrically disconnected? If yes: which sensors initiate Positive shut <br />Sensors; s -down? (Check all that apply) K Sump[Trench <br />❑ Yes <br />❑ No* <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑ Yes; ❑ No. <br />C� N/A <br />be <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is <br />installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what <br />does the <br />alarm trigger? % percent of tank capacity <br />❑ <br />® No <br />Was any monitoring 4quipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name <br />and model for all replacement parts in Section E, below. <br />Yes <br />❑ <br />No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; ElWater. If yes, describe causes in Section E, below. <br />Yes <br />i <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />® Yes <br />® Yes <br />❑ No* <br />❑ No* <br />Is all monitoring eq' "pent operational per manufacturer's specifications? <br />-- ---� • �•• ar u Wrc� urese uencfencfes were or will be corrected. <br />Comments: <br />Monitoring System Certification <br />F. In -Tank Gauging / SIR Equipment: <br />Page 2 of 4 <br />Check ' box if tank au ing is used only for <br />Check this box i no an gauging or equipment is installed. <br />Thiq -Minn mngt ha rmmnlptprf if in -tank nanninn Pnuinmpnf iq ngPrl to nPrform lack rfptprfinn mnnitnrinn <br />2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.