My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:03 PM
Creation date
11/8/2018 9:55:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 1998-2006.PDF
QuestysFileName
COMPLIANCE INFO 1998-2006
QuestysRecordDate
5/25/2016 9:55:35 PM
QuestysRecordID
3092689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY PR# <br /> VIRONMENTAL HEALTH DEPARTM T PAGE <br /> 34 E. Weber Ave., Third Floor, Stockton, CA 91!02 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Name Cht7PiV✓pa G/MY Facility Address \3'!7 S N T✓Ct 1 yr � <br /> Facility Contact FAk AAMM5 Title Phone # ��ZZ <br /> UST# I Product UST# Product 81 U T#�Product�_UST#_Product <br /> Overfill Prevention: L7'AudibleNisu I U Mechanical Monitoring Panel: Tlr� 3Sb <br /> Piping System: El Gravity C�7'f'ressure ❑SuctionViolations: ❑ M1-RDet CM2-Rprev 3-Both <br /> Automatic Pum Shut Down Satisfies CCR 2636(f)(5): la /es 0 No Designated Operator: IktN1 <br /> INSPECTION TYPE: utine DPol'onitoring Certification []Complaint ❑Install []Removal ❑Recptaiirr/Upp�grade <br /> COMPANY NAME: TECHNICIAN NAME: PHONE: Ow 1 g� <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 23 CCR 2643 (d) Daily monitoring of suction <br /> 2 CCR 2637 Secondary cont. testing piping (pre-1/1/84) <br /> 3 CCR 2711(b) & (c) Current State Forms A& B 24CCR 2636 (a) Conventional suction piping <br /> 4 HSC 25292.2 Certification of financial shall have continuous <br /> responsibility& CFO letter monitoring & 20 containment <br /> 5CCR 2632 (c)(2) UST monitoring is present(M1) 25 CCR 2643 (e) Biennial tightness test of gravit7 <br /> 6 CCR 2630 (d) UST system monitoring piping (pre-1/1/84) <br /> equipment is properly located to 26 CCR 2643 (d) Triennial line test for <br /> detect a leak (M1) conventional suction (pre- <br /> 7 HSC 25291 (b) UST system monitoring 1/1/84) (M1) <br /> equipment is operational (M1) 27 CCR 2661 Permit to repair UST system <br /> 8CCR 2636 (f)(1) Continuous monitoring system 28 HSC 25286 (a) Permit to alter monitoring <br /> for underground piping & UDC system <br /> is present (M1) 29 HSC 25298 (a) Illegal abandonment of UST <br /> 9 CCR 2636 (c)(1) All releases in secondary piping system <br /> flow to a collection sump 30 HSC 25298 (b) Permit to temporarily close USI <br /> 10 v/HSC 25291 (f) Line leak detector(s)(M1) system <br /> 11 HSC 25291(a)(2) Secondary containment for 31 HSC 25298 (c) Permit to close UST system <br /> UST is tight 32 HSC 25292.1 UST system is operated to <br /> 12 CCR 2635 (b)(1) Spill container(M2) prevent unauthorized release <br /> 13 HSC 25284.2 Annual spill container testing 33 CCR 2650 Recording/reporting <br /> 147CCR 2635 (b)(2) Overfill prevention system (M2) unauthorized release (M1) <br /> 15 CCR 2631 (a) Primary containment is product- 34 ✓ HSC 25291 (e) Water in 20 cont analyzed and <br /> tight properly disposed of <br /> 16 CCR 2632 (c)(2)(D)Monitoring & response plan 35 CCR 2640 (e) Single wall component within <br /> 17 CCR 2712 (i) Monitoring & response plan is 1000' of Public Well, no ELD <br /> on site 36 CCR 2635(a)(2)(A) Cathodic protection testing & <br /> 18 CCR 2712 (b) Maintenance &monitoring 60 day inspection log (M2) <br /> records(M1) 37 HSC 25299(a)(9) Disabling leak detect. Devices <br /> 19 CCR 2636 (f)(4) Annual line tightness test 38 CCR 2715(a) Statement from UST owner <br /> 20 CCR 2638 (a) Annual line leak detector test 39 CCR 2715(c) Monthly inspection by D.O, <br /> (M1) 40 CCR 2715 (f) D.O. trained employees <br /> 21 CCR 2638 (a) Annual monitoring certification 41 Violation(s) not listed above <br /> 22 CCR 2661 (f) Repair for tank/piping has had <br /> tightness test M2 <br /> EHDINSPECTOR: PHONE: <br /> RECEIVED BY: TITLE: <br /> Septic System: ❑Serves 2:20 persons/day ❑Receives other than sanitary waste <br /> Other Disposal Units identified: ❑Dry wells/French Drains <br /> C:OMUME-1 ja&k \LOCALS-1\Tev kUST Inspe iong,is0 DOC <br />
The URL can be used to link to this page
Your browser does not support the video tag.