My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:03 PM
Creation date
11/8/2018 9:55:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 1998-2006.PDF
QuestysFileName
COMPLIANCE INFO 1998-2006
QuestysRecordDate
5/25/2016 9:55:35 PM
QuestysRecordID
3092689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING PROCEDURES DOUBLE CONTAINED PIPING <br /> CONTINUOUS ELECTRONIC MONITORING SUMPS <br /> E::: - <br /> DOUBLE CONTAINED PIPING <br /> INTERSTITIAL SPACE MONITOR: X LIQUID <br /> SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS350 Single Float Series 794390-208 <br /> EQUIPMENT AT THIS FACILITY IS: Veeder-Root TLS-350 PLLD Series 848480-001 <br /> All double contained piping is continuously monitored electronically by a system that can sense a leak at <br /> of 3 gallons or more per hour at 10 lbs. per square inch of line pressure within 1 hour at more than one <br /> location with positive shut down. If the pressure sensor is activated, the line pressure monitor is <br /> capable of sensing the pressure loss in the system and disables the flow of product through the lines. <br /> All product lines are sloped down towards the tank, and any liquid in the annular space will flow <br /> backwards into the sump area. There is a sensor in the sump area that detects any liquid present there. <br /> The system has both visible and audible alarms that are activated when there is liquid in the sump or <br /> detected in the secondary containment. At least annually, the system is capable of detecting a release <br /> from the primary piping equivalent to .1 gph defined at 150% operating pressure. <br /> RESPONSE PLAN <br /> If the system goes into the alarm mode, the Operator or his designate will check the alarm panel to verify <br /> that there is a leak condition and then silence the audible alarm. The Operator or his designee will <br /> immediately contact Chevron dispatch and advise them of the situation so that they can contact the <br /> appropriate personnel who will follow the instructions outlined in the "Leak Response Plan", which is part <br /> of your Hazardous Material Management Plan. All follow up will be completed within the month the <br /> problem occurred. <br /> DISPENSER CONTAINMENT <br /> SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS-350 Single Float Series 794390-208 <br /> All dispensers are double contained with fiberglass pans that are continuously monitored electronically <br /> using liquid sensors. The system has both visible and audible alarms that are activated when liquid is <br /> detected. <br /> The monitoring system will be inspected daily. The Operator or an employee appointed by the Operator <br /> will follow the same procedures as outlined for monitoring the double contained product tanks. <br /> PREVENTATIVE MAINTENANCE <br /> The monitoring equipment shall be inspected and certified annually. Maintenance will be performed <br /> annually or as needed. All work performed to the monitoring system will be in accordance to the <br /> manufacturers recommendations. <br /> TRAINING <br /> Tank operators are trained on the proper operations of the monitoring equipment per the manufacturer's <br /> instructions. <br /> Chevron Emergency Information Center(CEIC) 1-800-231-0623 <br /> Chevron Maintenance Dispatch 1-800-423-3528 <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.