My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:03 PM
Creation date
11/8/2018 9:55:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 1998-2006.PDF
QuestysFileName
COMPLIANCE INFO 1998-2006
QuestysRecordDate
5/25/2016 9:55:35 PM
QuestysRecordID
3092689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
02/19/2003 16:36 FAX 9258425660, CHEVRON PRODUCTS COMPANY IM002 <br /> 2-14-03: 9:OOAM: :925 551 7888 N 3/ 4 <br /> r� \I <br /> D. Results of Testing/Servicing <br /> ` Software Version Installed: <br /> Com tete the following checklist: <br /> Yes ❑ No* Is the audible ahunnoperational? <br /> Yes ❑ No* Is the visual alann o erationa17 <br /> yes ❑ No* Were ali sensors visually ins ected,functionally tested,and confirmed o erationa17 <br /> r[]�yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> rT not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> TdDN/A operational? <br /> es ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) �Mmp/french Sensors; $;Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks&4 sensor failure/disconnection? Mr[ea; ❑No. <br /> ❑ Yes ❑ No* .For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> t�LVA mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill poin s and operating property? If so,at what percent of tank capacity does the alarm trigger? % <br /> Yes* ❑ No Was any monitoring equipment replaced7 if yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)❑ <br /> Frodud; ater. if yes, describe causes in Section E,below. <br /> �Wl-Yes ❑ No* Was monitoring!stern set-up,reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ❑ No* Is all onitorin a of mento rational per manufacturer's spec <br /> Yes m <br /> itications? <br /> •In Section E below, describe how and when these deficiencies were or will be corrected. <br /> E. Comments: _ <br /> K UP�2 T�t Pwt t/;A /6 05— i D '!5Cyoc� <br /> Page 2 of 3 03101 <br />