Laserfiche WebLink
SAN JOAQUIN COUNTY DATE PR# 0 o o o Z <br /> O <br /> *VNVIRONMENTAL HEALTH DEPARThT�NT PAGE <br /> 304 E.Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility NameC-n'"ro.J t- f%?-t0 Facility Address 'I-7 -7S 0. 7-r,4C V 191 1) <br /> Facilty Contact C•S. SU+LPI Title � A �d� Phone# S 36- 4(-l2 Z <br /> UST#S Producta UST#Product (�S UST# Product "'� UST#_Product <br /> 12th IZ1I12th <br /> Overfill Prevention: )(Audible/Visual O Mechanical Monitoring Panel: V P, TL S - 35-6 <br /> Piping System: ❑ Gravity (Pressure ❑ Suction Violations: ;Minor El Major <br /> Automatic Pum Shut Down Sa isfies CCR 2636 Yes O No Dispenser Pan: gra <br /> Yes O No <br /> INSPECTION TYPE: routine )Monitoring Certification OComplaint ❑Install ❑Removal ❑Repair/Upde <br /> COMPANY NAME: TECHNICIAN NAME: 00111J MAI IniAt_ PHONE: 36-5 /2C4 <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance & monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> / month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3 V CCR 2711(b)& (c) Current State Forms A& B 22 CCR 2630 (d) Annual line leak detector test <br /> 4 HSC 25292.2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring &20 containment <br /> :7_\�_HSC 25291 (e) Water in secondary (20)cont 26 CCR 2643 (e) Biennial tightness test of gravity <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system / system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636 (f)(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13 CCR 2635 (b)(1) Spill container 31 HSC 25298 (b) Permit to temporarily close UST <br /> 14 CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1000'of Public Well, no ELD <br /> unauthorized release 35 CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 CCR 2632 (d) Monitoring &response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19 CCR 2712 (i) Monitoring & response plan is 37 Violation(s)not listed above <br /> on site p <br /> EHD INSPECTOR: �� VON PHONE: -/{ b 9F y 0 <br /> RECEIVED BY: TITLE: <br /> UNMUUSTANSP(rev 724/02) <br />