Laserfiche WebLink
Benefits of <br />Fiberglass Piping <br />in Underground <br />Fuel Applications <br />TIME TESTED <br />• 30-Year Warranty <br />• Installed since 1964 <br />• Never been removed due <br />to fuel incompatibility <br />• Total immersion testing <br />in fuels <br />• Case History G7301 <br />LOWEST TOTAL COST <br />OF OWNERSHIP <br />• No reinstall costs due <br />to fuel incompatibility <br />• Homogencus system: no <br />liner, no bladder <br />A TRUE PIPE IN A PIPE <br />• Interstitial space <br />cunmunication <br />• Leak prevention, not <br />leak detecticn <br />• INSTALL IT, BURY IT, <br />FORGET IT! <br />2 <br />UL/ULC Listed Red Thread® IIA Piping System <br />• Thirty Year <br />Warranty* <br />— With over 40 <br />years proven <br />performance in <br />the marketplace, <br />Underwriter's <br />Laboratories, Inc. <br />and Underwriter's Laboratories <br />Canada (UL/ULC) Listed RED <br />THREAD HA pipe, fittings and <br />adhesive carry a 30-year warranty <br />The product is warranted to be <br />free from defects in material and <br />workmanship—and against internal <br />and external corrosion—when used <br />for underground transportation of <br />fuels. <br />• Leak Prevention — Sump <br />entry/termination fittings provide <br />positive seal at the sump to help <br />prevent leaking of underground <br />fuel in or out of the sump. This <br />fitting also helps provide Class <br />I (leak prevention) protection <br />which complies with California's <br />requirement for continuous <br />interstitial monitoring of the piping <br />system's secondary containment. <br />• Exceptional Flow <br />Characteristics - Two-inch <br />RED THREAD IIA pipe has the <br />largest I.D. (2.235") in the fueling <br />industry—allowing you to sell twice <br />the fuel per foot than any 1 1 /2 " <br />flexible product on the market. <br />Three-inch RED THREAD IIA <br />fiberglass pipe has a nominal 3.36" <br />I.D.; four-inch pipe has a 4.36' I.D. <br />• Outstanding Corrosion <br />Resistance — RED THREAD IIA <br />piping systems resist internal and <br />external corrosion from hazardous <br />soils, fuels and other corrosive <br />fluids. <br />• Quality Assurance — Smith <br />Fibercast quality assurance <br />procedures meet or exceed the <br />test requirements of UL/ULC. <br />• Permeability — RED THREAD <br />IIA permeability resistance greatly <br />exceeds UL allowable permeability. <br />The data below is based on 30 <br />days. <br />2004 UL 971: <br />Primary - 1 gm/m 2/day <br />(0.053 gal/100 ft. of 2" pipe, <br />30 days) <br />Secondary - 4 gm/m 2 /day <br />(0.213 gal/100 ft. of 2" pipe, <br />30 days) <br />1995 UL 971: <br />Primary - 4 gm/m 2/day <br />(0.213 gal/100 ft. of 2" pipe, <br />30 days) <br />Secondary - 24 gm/m 2 /day <br />(1.278 ga1/100 ft. of 2" pipe, <br />30 days) <br />Old vs New - Pipe in the foreground was <br />installed in 19 73 and removed 27 years <br />later when the station closed. <br />PAGE 75 <br />Lowest Total Cost Ownershipt <br />[Material Cost + Installation Cost] -:- System Life <br />1 Maintenance cost and replacement cost not required with RED THREAD IIA piping system. <br />'Please review SmIth Fibercast's wrItten warranty to determine the terms and conditions.