INSTALL 2017 INSTALL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10715
>
2300 - Underground Storage Tank Program
>
PR0541281
>
INSTALL 2017 INSTALL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 4:14:46 PM
Creation date
11/8/2018 9:55:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2017 INSTALL
RECORD_ID
PR0541281
PE
2361
FACILITY_ID
FA0023650
FACILITY_NAME
Trinity Parkway AMPM ARCO #83819
STREET_NUMBER
10715
STREET_NAME
TRINITY
STREET_TYPE
Pkwy
City
Stockton
Zip
95219
APN
6602002
CURRENT_STATUS
01
SITE_LOCATION
10715 Trinity Pkwy
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRINITY\10715\PR0541281\2017 INSTALL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
339
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Explain how communication can be demonstrated throughout the hydrostatic monitored interstitial <br />spaces of the vent line transition sump and under dispenser containment (UDC) surnps, <br />Hydrostatic liquid communication must be demonstrated at the far ends of all interstitial spaces. Each <br />double-wailed hydrostatic sump must be tested throughout the sump. Include a drawing of all test ports <br />used to test communication. Typically, a minimum of two test ports in each hydrostatically monitored <br />sump, UDC and vent sump is necessary to verify communication of the interstitial fluid throughout the <br />sump, <br />The plans show the fill and turbine sump interstitial ftuid communicat on (2`16 ) ports. <br />The vent and under dispenser containment sump drawings G06( 2, M.5.3,22, M.5.3,23) do not show <br />the interstitial fluid communication (2'1) ports. <br />3 The plans must show the vacuum monitored zones. List the vacuum sensors and the zones they will <br />monitor Include all product, vent and vapor recovery piping secondary containment. <br />Response: Comments 2 and 3 were reflected in revised plan sheets delivered to your office on 4/20/17. <br />Please let me know if you need anything else and thank you for your patience. <br />From: Garrett Backus [EH] [mailto:gbackus@sjcehd.com] <br />Sent: Friday, April 28, 2017 11:58 AM <br />To: Leslie Burnside <br />Subject: RE: Arco Trinity Pkwy, Stockton - BCE #16700 - Revised Sheets and Responses <br />And Hosemaster cert (I was sent Flex-ing cert previously) <br />From: Garrett Backus [EH] <br />Sent: Friday, April 28, 2017 11:57 AM <br />To: Leslie Burnside (Iburnside@barghausen.com ) <br />Subject: FW: Arco Trinity Pkwy, Stockton - BCE #16700 - Revised Sheets and Responses <br />Leslie, <br />I still need to get updated certifications for Latham Zubillaga for Xerxes tank, Veeder Root level 4 TLS-3XX <br />Garrett Backus, Ld. Sr. REHS, CUPA programs <br />San Joaquin County Environmental Health Department <br />1868 E Hazelton Ave, Stockton, CA 95205 <br />(209) 468-2986 (phone) (209) 468-3433 (fax) <br />gbackus@sjcehd.com http:/ /www.sjcehd.com/ <br />From: Leslie Burnside [mailtokurnside@barghausen.com ] <br />Sent: Tuesday, April 18, 2017 2:26 PM <br />To: Garrett Backus [EH] <br />Subject: RE: Arco Trinity Pkwy, Stockton - BCE #16700 - Revised Sheets and Responses <br />2