INSTALL 2017 INSTALL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10715
>
2300 - Underground Storage Tank Program
>
PR0541281
>
INSTALL 2017 INSTALL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 4:14:46 PM
Creation date
11/8/2018 9:55:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2017 INSTALL
RECORD_ID
PR0541281
PE
2361
FACILITY_ID
FA0023650
FACILITY_NAME
Trinity Parkway AMPM ARCO #83819
STREET_NUMBER
10715
STREET_NAME
TRINITY
STREET_TYPE
Pkwy
City
Stockton
Zip
95219
APN
6602002
CURRENT_STATUS
01
SITE_LOCATION
10715 Trinity Pkwy
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRINITY\10715\PR0541281\2017 INSTALL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
339
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Guide Specifications - Xerxes® Fiberglass Underground Storage Tanks <br />Short form: <br />The contractor shall provide a single-wall, double-wall or triple-wall <br />fiberglass reinforced plastic (FRP) Underwriters Laboratories-labeled un- <br />derground storage tank as shown on the drawings. The tank size, fit- <br />tings and accessories shall be as shown on the drawings. The fiberglass <br />tank shall be manufactured by Xerxes® Corporation. <br />The tank shall be tested and installed according to the Xerxes Installa- <br />tion Manual and Operating Guidelines for Fiberglass Underground <br />Storage Tanks in effect at time of installation. <br />Long form: <br />Part I: General <br />1.01 Quality Assurance <br />A. Acceptable Manufacturer: Xerxes Corporation <br />B. Governing Standards, as applicable: <br />1. Underwriters Laboratories (UL) Standard for Safety 1316 for <br />storage of flammable liquids. A UL label shall be attached to <br />each tank. <br />2. National Fire Protection Association (NFPA) Standards: <br />NFPA 30: Flammable and Combustible Liquids Code <br />NFPA 30A: Automotive and Marine Service Station Code <br />NFPA 31: Installation of Oil-Burning Equipment. <br />3. City of New York Department of Buildings M.E.A., Division <br />#161-89-M. <br />Part II: Products <br />2.01 Single-wall, Double-Wall and Triple-Wall Fiberglass Reinforced <br />Plastic (FRP) Underground Storage Tanks: <br />A. Loading Conditions - Tank shall meet these design criteria: <br />1. Internal Load - Single-wall, double-wall and triple-wall tank <br />shall withstand a 5-psig air-pressure test with 5:1 safety factor. <br />Contractor shall individually test tanks for leakage prior to in- <br />stallation. Maximum test pressure is 5 psig (3 psig for a 12'-di- <br />ameter tank). <br />2. Vacuum Test - To verify structural integrity, every standard 10'- <br />diameter tank and smaller shall be vacuum-tested by the manu- <br />facturer at the factory to 11.5" of mercury. All 12'-diameter <br />tanks shall be tested by the manufacturer to 5.5" of mercury. <br />3. Surface Loads-Tank shall withstand surface H-20 axle loads <br />when properly installed according to Xerxes' current Installation <br />Manual and Operating Guidelines. <br />4. External Hydrostatic Pressure - Tank shall be capable of being <br />buried in ground with 7' of overburden over the top of the <br />tank, the hole fully flooded and a safety factor of 5:1 against <br />general buckling. <br />5. Tank shall support accessory equipment - such as heating coils, <br />drop tubes, submersible pumps and ladders - when properly in- <br />stalled. <br />B. Product Storage: <br />1. Tank shall be capable of storing petroleum products with spe- <br />cific gravity up to 1.1. <br />2. Tank shall be vented to atmospheric pressure. <br />3. Tank shall be capable of storing products identified in the man- <br />ufacturer's current standard limited warranty. <br />C. Materials: <br />1. Tank shall be manufactured with 100% resin and glass-fiber re- <br />inforcement. No sand fillers. <br />D. Tank Dimensions (Refer to Xerxes literature on gallonage.): <br />1. Tank shall have nominal capacity of gallons. <br />2. Tank shall have nominal outside diameter of feet. <br />E. Interstitial Space <br />1. Double-wall and triple-wall tank shall have a space between the <br />walls to allow for the free flow and containment of leaked <br />product from the primary tank. The space also allows the inser- <br />tion of a monitoring device through a monitoring fitting. <br />2.02 Accessories <br />A. Optional Anchor Straps <br />1. Straps shall be FRP anchor straps as supplied by tank manufac- <br />turer. <br />2. Number and location of straps shall be specified in current liter- <br />ature by tank manufacturer. <br />B. Manways <br />1. All manways shall be flanged and 22" ID., complete with UL- <br />listed gaskets, bolts and covers. (30" and 36"I.D. manways are <br />also available on certain larger tanks.) <br />2. Location is shown on tank drawings. <br />3. Optional manway extensions shall be FRP and inches <br />long. <br />4. All 12'-diameter tanks require at least one manway. <br />C. Optional Fill Tubes <br />1. Fill tubes shall be FRP, 4" in diameter, with a 6" x 4" double- <br />tapped reducer bushing, and include a 6" NPT fitting. Tubes <br />shall terminate a minimum of 4" from the bottom of tank (a <br />minimum of 6" for a 12'-diameter tank). <br />D. Striker Plates <br />1. Striker plates shall be installed under each service fitting and <br />manway opening. <br />E. Optional Heating Coils <br />1. Optional heating coils shall be installed in a separate 22"-diam- <br />eter manway and shall be as supplied by tank manufacturer. <br />F. Optional Ladders <br />1. Ladders shall be the standard ladder as supplied by tank manu- <br />facturer (aluminum, carbon steel or fiberglass). <br />G. NPT Threaded Fittings <br />1. All NPT threaded fittings shall be a material of construction con- <br />sistent with the requirements of the UL label. <br />2. All standard threaded fittings shall be half-couplings and shall <br />be 4" or 6" in diameter. Reducers are to be used for smaller <br />sizes where shown and provided by contractor. <br />3. Strength - NPT fittings shall withstand a minimum of 150 foot- <br />pounds of torque and 1,000 foot-pounds of bending, both with <br />a2:1 safety factor. <br />H. Monitor Fittings <br />1. The monitor fitting for a double-wall and triple-wall tank shall <br />consist of a 4" NPT fitting on the tank. <br />2.03 Optional Monitoring System <br />A. General <br />1. The tank manufacturer shall offer the option of a continuously <br />monitored, hydrostatic leak-detection system for its double- and <br />triple-wall tanks. <br />2. The monitoring system shall be designed by the manufacturer <br />to detect a leak in either the primary, secondary or tertiary tank, <br />at installations with or without groundwater. <br />3. The monitoring system shall include monitoring fluid in the pri- <br />mary interstice delivered to the installation site. The contractor <br />shall be responsible for field installation of monitoring fluid in <br />the secondary interstice. <br />4. The reservoir(s) shall be fitted with one 4" NPT fitting for instal- <br />lation of an electronic, reservoir-level sensor. <br />Part III: Testing and Installation <br />3.01 Testing <br />A. Testing - Tank shall be tested according to the applicable Xerxes <br />Installation Manual and Operating Guidelines in effect at time of <br />installation. <br />3.02 Installation <br />A. Installation - Tank shall be installed according to the applicable <br />Xerxes Installation Manual and Operating Guidelines in effect at <br />time of installation. <br />Part IV: Limited Warranty <br />4.01 Limited Warranty <br />A. Limited Warranty - Warranty shall be manufacturer's standard lim- <br />ited warranty in effect at time of purchase. <br />8