My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
INSTALL_2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:22:40 PM
Creation date
11/8/2018 9:57:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2012
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\V\VALPICO\550\PR0536555\INSTALL PLAN 2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Guide Specifications - Xerxes* Fiberglass Underground Storage Tanks <br /> Short form: 2.02 Accessories <br /> The contractor shall provide a single-wall,double-wall or triple-wall A. Optional Anchor Straps <br /> fiberglass reinforced plastic(FRP)Underwriters Laboratories-labeled un- 1.Straps shall be FRP anchor straps as supplied by tank manufac- <br /> derground storage tank as shown on the drawings.The tank size,fit- turer. <br /> tings and accessories shall be as show®on the drawings.The fiberglass 2.Number and location of straps shall be specified in current liter- <br /> tank shall be manufactured by Xerxes Corporation. _ <br /> ature by tank manufacturer. <br /> The tank shall be tested and installed according to the Xerxes Installa- B. Manways <br /> tion Manual and Operating Guidelines for Fiberglass Underground 1.All manways shall be flanged and 22' I.D.,complete with UL- <br /> Storage Tanks in effect at time of installation. listed gaskets,bolts and covers.(30' and 36'I.D. manways are <br /> also available on certain larger tanks. - <br /> 2.Location is shown on tank drawings. <br /> Long form: 3.Optional manway extensions shall be FRP and_inches <br /> Part I: General long. <br /> 7.01 Quality Assurance 4. All 12'-diameter tanks require at least one manway. <br /> A. Acceptable Manufacturer:Xerxes Corporation C. Optional Fill Tubes <br /> B. Governing Standards,as applicable: 1.Fill tubes shall be FRP,4' in diameter,with a 6' x 4' double- <br /> 1.Underwriters Laboratories(UL)Standard for Safe 1316 for tapped reducer bushing,and include a 6° NPT fitting.Tubes <br /> Safety shall terminate a minimum of 4'from the bottom of tank(a <br /> storage of flammable liquids.A UL label shall be attached to minimum of 6' for a 12'-diameter tank). <br /> each tank. <br /> 0. Striker Plates <br /> 2.National Fire Protection Association(NFPA)Standards: 1.Striker plates shall be installed under each service fitting and <br /> NFPA 30:Flammable and Combustible Liquids Code manway opening. <br /> NFPA 30A:Automotive and Marine Service Station Code <br /> NFPA 31:Installation of Oil-Burning Equipment. E. Optional Heating Coils <br /> 3.City of New York Department of Buildings M.E.A.,Division 1.Optional heating coils shall be installed in a separate 22°-diam- <br /> #161-89-M. eter manway and shall be as supplied by tank manufacturer. <br /> Part II: Products F. Optional Ladders <br /> 2.01 Single-wall,Double-Wall and Triple-Wall Fiberglass Reinforced 1.Ladders shall be the standard ladder as supplied by tank manu- <br /> Plastic(FRP)Underground Storage Tanks: facturer(aluminum,carbon steel or fiberglass). <br /> A. Loading Conditions-Tank shall meet these design criteria: G. NPT Threaded Fittings <br /> 1. Internal Load-Sin le-wall,double-wall and triple-wall tank 1.All NPT threaded fittings shall be a material of construction con- <br /> 9 P sistent with the requirements of the UL label. <br /> shall withstand a 5-psig air-pressure test with 5:1 safety factor. lf <br /> d threaded fittings shall be standard 2_All sthalf-couplings and shall <br /> Contractor shall individually test tanks for leakage prior to in- be or r in diameter.Reducers are ha be used for smaller <br /> stallation.Maximum test pressure is 5 psig(3 psig for a 12'-di- <br /> ameter tank). sizes where shown and provided by contractor. <br /> 2.Vacuum Test-To verify structural integrity,every standard 101- 3.Strength-NPT fittings shall withstand a minimum of 150 foot- <br /> diameter tank and smaller shall be vacuum-tested by the manu- pounds of torque and 1,000 foot-pounds of bending,both with <br /> facturer at the factory to 11.5' of mercury.All 12'-diameter a 2:1 safety factor <br /> tanks shall be tested by the manufacturer to 5.5' of mercury. H. Monitor Fittings <br /> 3.Surface Loads-Tank shall withstand surface H-20 axle loads 1.The monitor fitting for a double-wall and triple-wall tank shall _ <br /> when properly installed according to Xerxes'current Installation consist of a 4' NPT fitting on the tank. <br /> Manual and Operating Guidelines. 2.03 Optional Monitoring System <br /> 4. External Hydrostatic Pressure-Tank shall be capable of being A. General <br /> buried in ground with 7'of overburden over the top of the The tank manufacturer shall offer the option of a continuously 1. <br /> tank,the hole fully flooded and a safety factor of 5:1 against monitored,hydrostatic leak-detection system for its double-and <br /> general buckling. triple-wall tanks. <br /> 5.Tank shall support accessory equipment-such heating coils, 2.The monitoring system shall be designed by the manufacturer <br /> drop tubes,submersible pumps and ladders-whh when properly in- <br /> stalled. to detect a leak in either the primary,secondary or tertiary tank, - <br /> at installations with or without groundwater. <br /> B. Product Storage: 3.The monitoring system shall include monitoring fluid in the pri- <br /> 1.Tank shall be capable of storing petroleum products with spe- maty interstice delivered to the installation site.The contractor <br /> cific gravity up to 1.1. shall be responsible for field installation of monitoring fluid in <br /> 2.Tank shall be vented to atmospheric pressure. the secondary interstice. <br /> 3.Tank shall be capable of storing products identified in the man- 4.The reservoir(s)shall be fitted with one 4' NPT fitting for instal- <br /> ufacturer's current standard limited warranty. lation of an electronic,reservoir-level sensor. <br /> C. Materials: Part III:Testing and Installation <br /> 1.Tank shall be manufactured with 100% resin and glass-fiber re- 3.01 Testing <br /> inforcement.No sand fillers. A. Testing-Tank shall be tested according to the applicable Xerxes <br /> D. Tank Dimensions(Refer to Xerxes literature on gallonage.): Installation Manual and Operating Guidelines in effect at time of <br /> 1.Tank shall have nominal capacity of gallons. installation. <br /> 2.Tank shall have nominal outside diameter of_feet. 3.02 Installation <br /> E. Interstitial Space A. Installation-Tank shall be installed according to the applicable <br /> 1.Double-wall and triple-wall tank shall have a space between the Xerxes Installation Manual and Operating Guidelines in effect at <br /> walls to allow for the free flow and containment of leaked time of installation. <br /> product from the primary tank.The space also allows the inser- Part IV.Limited Warranty - <br /> tion of a monitoring device through a monitoring fitting. 4.01 Limited Warranty <br /> A. Limited Warranty-Warranty shall be manufacturer's standard lim- <br /> ited warranty in effect at time of purchase. <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.