5. If your sumps had vacuum,proceed with the installation per the products respective Installation Manual.Yew them HERE. <br /> 6. If your sumps did not hold vacuum,call Bravo systems with the results of your testing so we can better help you. <br /> If you are shipped replacement gauges:After you install them per the provided instructions, follow the <br /> overnight vacuum test outlined in#4 above to conduct a factory test of a re-sealed interstice. <br /> 09:What common types of repairs are allowed on Bravo shallow pans? Read installation instructions on <br /> Bravo B2000 Shallow pans to see if they clarify how to repair various problems. <br /> • For B-18-3'Black Plastic Compression fittings leaking between gasket and pipe. Use WR-3 wrench <br /> to loosen seal between nut and doughnut gasket.Apply wet-dry grease between nut and gasket to allow <br /> nut to easily make a compression seal. If you can not get grease between nut and gasket spray WD-40 <br /> between surfaces to lubricate hard to reach areas. Then compress nut to%to%turns past hand tight. <br /> • For Electrical fittings that do not have a seal or are leaking. If possible retrofit a compression fitting <br /> that seals to both the conduit and Bravo fitting. Blue Line has a split electrical fitting for this application. If <br /> split fittings do not apply, then use adhesive to seal annular space by first cleaning and prepping the area <br /> around conduit and fitting to remove all contaminates that will prevent bonding of adhesives. Pack <br /> annular space and seal area with one of three recommended adhesives: Bravo Vulkem sealant(VS), <br /> PetroSeal or Bravo 8400-Adhesive Kit. <br /> • For Shallow Pans with Divider Tabs-Required to electronically monitor each section?You have an <br /> option. You are authorized to remove the liquid divider(s)or a portion of them. You need only to remove <br /> an area of a few inches from each divider to facilitate unrestricted liquid communication between the <br /> previously isolated containment zones. <br /> 1. Remove all mechanical float trip mechanisms and their assemblies. <br /> 2. Remove any sealant at the divider area you wish to remove. <br /> 3. Using Tin-Snips,ship the divider vertically in two places and remove the loose piece. <br /> 4. Seal arty metal that was cut,scratched or dinged with Vutkem sealant or PetroSeal to prevent against corrosion. <br /> 5. Use water to determine which Float cup qualifies as the lowest point. <br /> 6. Remove all liquids from the sump.Clean and dry the sump interior. <br /> 7. Install the sensor to that cup(lowest point)and mark sump so future maintenance technicians will rot move the sensor to <br /> another Float cup. <br /> GUIDELINES: No exposed Steel. No power tools on the dividers. Electronic Sensor must <br /> be placed at the lowest point. <br /> • How can I clean up the bottom of a Steel Dispenser Containment unit?Follow this procedure: <br /> A) Use any solvent or cleaning solution you prefer. <br /> B)Scrape the bottom and/or walls with a flat-blade tool. <br /> C)Vacuum out any liquids, gunk, etc.. <br /> D)Acetone to clean the surfaces so a visual inspection can be made. <br /> E) Lightly sand all areas where the factory epoxy-paint is missing. <br /> F) Dust, blow out and/or vacuum any debris from the interior. <br /> G) Protect any exposed test ports or threads, remove any electronic sensors. <br /> H)Coat the interior well with AmerShield, covering all exposed steel. <br /> For Product Information on AmerShield, Click Here. <br /> For Information on Surface Preparation, Click Here. <br /> Note:Always check with you local regulatory authority for additional guidelines and permitting. <br /> 010:Can I modify or repair a Bravo Conversion Frame? <br /> A:No. Under no circumstances can you modify, repair or add to a Bravo Systems Dispenser Conversion Frame <br /> (CONV-B2000)unless authorized in writing by the factory. <br /> When authorized, typical allowances include opening a We in the drainage louver panels only to allow conduit to pass through from <br /> below. In this specific case,the hole cut must conform to the O.D.of the conduit as closely as possible. Proper surface preparation and <br /> cleaning is necessary,followed by a heavy application of Vulkem 116 sealant. If this process is conducted on a site without proof of <br /> written authorization from Bravo,that installation is non-compliant and should be replaced or addressed per all local codes,reguations or <br /> applicable laws. <br /> http://www.sbmvo.com/faq.htrn <br />