Laserfiche WebLink
UL/ULC Listed Red Thread® IIA Piping System <br /> Lowest Total Cost Ownershipt <br /> Benefits of (Material Cost + Installation Cost] _ System Life <br /> t Maintenance cost and replacement cost not required with RED THREAD IIA piping system. <br /> Fiberglass Piping Thirty Year • outstanding Corrosion <br /> in UndergroundW a r r a n t y " Resistance — RED THREAD IIA <br /> With over 40 piping systems resist internal and <br /> Fuel Applications years proven external corrosion from hazardous <br /> performance in soils, fuels and other corrosive <br /> TIME TESTED the marketplace, fluids. <br /> Underwriter ' s <br /> • 30-Year Warranty Laboratories, Inc. • Quality Assurance — Smith <br /> and Underwriter's Laboratories Fibercast quality assurance <br /> Installed since 1964 Canada (UL/ULC) Listed RED procedures meet or exceed the <br /> THREAD IIA pipe, fittings and test requirements of UL/ULC. <br /> adhesive carry a 30-year warranty. <br /> • Never been removed due The product is warranted to be • Permeability — RED THREAD <br /> to fuel incompatibility free from defects in material and IIA permeability resistance greatly <br /> workmanship—and against internal exceeds UL allowable permeability. <br /> •Total immersion testing and external corrosion—when used The data below is based on 30 <br /> in fuels for underground transportation of days. <br /> fuels. <br /> 2004 UL 971: <br /> • Case HistoryG7301 . Leak Prevention — Sump Primary - 1 gm/m2/day <br /> entry/termination fittings provide (0.053 gaV100 ft. of 2" pipe, <br /> positive seal at the sump to help 30 days) <br /> LOWEST TOTAL COST prevent leaking of underground Secondary- 4 gm/ml/day <br /> OF OWNERSHIP fuel in or out of the sump. This (0.213 gal/100 ft of 2" pipe, <br /> fitting also helps provide Class 30 days) <br /> • No reinstall costs due I (leak prevention) protection 1995 UL 971: <br /> to fuel incompatibility which complies with California's Primary- 4 gm/m2/day <br /> requirement for continuous (0.213 gal/100 ft of2" pipe, <br /> interstitial monitoring of the piping 30 days) <br /> Homogenous system: no Secondary- 24 gm/m2/day <br /> liner, no bladder system's secondary containment (1.278 gaV100 ft. of 2" pipe, <br /> • Exceptional Flow 30 days) <br /> A TRUE PIPE IN A PIPE Characteristics - Two-inch . <br /> RED THREAD IIA pipe has the <br /> • Interstitial space largest I.D. (2.235") in the fueling L <br /> communication industry—allowing you to sell twice , <br /> the fuel per foot than any 11/2" <br /> • Leak prevention, not flexible product on the market. -- _ 10 <br /> leak detection Three-inch RED THREAD IIA Old vs New-Pipe in the foreground was <br /> fiberglass pipe has a nominal 3.36" installed in 1973 and removed 27 years <br /> • INSTALL IT BURYITI.D., four-inch pipe has a 4.36" I.D. later when the station closed. <br /> , <br /> FORGETIT! <br /> 'Please review Smith Fibercast's written warrantyto determine the terms and conditions. <br /> 2 <br /> PAGE 75 <br />