Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
6732
>
2300 - Underground Storage Tank Program
>
PR0231830
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:38:43 PM
Creation date
11/8/2018 9:59:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231830
PE
2361
FACILITY_ID
FA0004030
FACILITY_NAME
THREE PALMS GROCERY
STREET_NUMBER
6732
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10110001
CURRENT_STATUS
02
SITE_LOCATION
6732 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WATERLOO\6732\PR0231830\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEN UST INSTALLATION INSPECTION RECORD - p' <br /> FACILITY NAME: Q S — ADDRESS: A 73 Lit, C <br /> FACILITY (D# <br /> V TANK# ULS TANK MODEL/M IAL: <br /> CAPACITY: PRODUCT: Q u L R.E.H.S: `� ) <br /> l ODd <br /> A [ <br /> P N ALL TANKS i0 BE INSTALLED AND TESTED IN ACCORDANCE <br /> P I WITH MANUFACTURER WRITTEN SPECIFICATIONS <br /> R T <br /> 0 I <br /> V A <br /> E L <br /> 0 S <br /> ITEM OR EauiPMENT INSPECTED <br /> DATE <br /> 1. UST PLANS SUBMITTED/ FEES PAID (H+S CODE 25287) <br /> 2. UST INSTALLATION PLANS APPROVED <br /> INITIAL INSPECTIONS <br /> 3, INSPECTION AND TEST OF SECONDARY CONTAINMENT: HOLIDAY: <br /> VACUUM: SOAP: PSI: HRS/MIN: BRIME(LIOUID ANNULAR): OTHER: <br /> 4, PRIMARY TANK TEST: PSI: HRS/MIN: <br /> 5. TANK APPROPRIATELY PLACED WITH APPROVED BACKFILL (API/PES) <br /> PIPING INSPECTIONS 140 f <br /> VO j t -Jtp-I+, 6. PRIMARY PIPING TEST (MINIMUM 40 PSI/30 MIN) (CCR 2636 Cell <br /> SP` I 7. SECONDARY PIPING CONTAINMENT TEST PSI: NRS/MIN: OTHER:J (CCR 2636 (e)) <br /> �Q '��IK.O QI ✓ LAKE TEST ON ALL SUMPS (24 HR. MINIMUM)- HRS: (CCR 2635 (a) (4)) <br /> ✓ UNUSED TANK OPENINGS SEALED AND CORROSION PROTECTED PEI <br /> 1po 1, OVERSPILL PERFORMANCE TEST (CCR 2635 (b) (1) (C)) <br /> 1 I 1L ALL PIPING AND FITTINGS CORROSION PROTECTED (CCR 2636 (b)) <br /> 12. PIPING SLOPES TO COLLECTION SUMP (CCR 2636 (041)) <br /> FINAL INSPECTION <br /> f_�„ v *3, PERFORMANCE TEST FOR "ALV' MONITORING PROBES (CCR 2632 (C) (2)) <br /> oV '��� 9 1 � - PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM (PANEL) (CCR 2632 (C) (2)) <br /> Q 1 1 u15. PERFORMANCE TEST OF LINE LEAK DETECTION (CCR 2643 (C) (1)) <br /> VA <br /> 16. PERFORMANCE TEST OF AUTOMATIC PUMP SYSTEM SHUT,aF—, CCR 2636 (9)) <br /> 17. BALL FLOAT VALVES INSTALLED r6 mzryCd„ <br /> OVERFILL PROTECTION INSTALLED/APPROVED (CCR 2635 (b) (2)) <br /> V� TANK ACCESS PORTS 3ROUGHT TO GRADE (LOCKED ANO.WATERTIGHT) API <br /> IDD <br /> '� p TANK INTEGRITY TEST (PASSING HARD COPY) And, - � <br /> ( Y( !j dd (CCR 2635 (a) (5)) <br /> OO I ��../ J1. MONITORING PLAN, RESPONSE PLAN AND LOG 300K ON SITE (CCR 2632 (d)) <br /> 22. "C" FORM COMPLETED AND SUBMITTED - (CCR 2635 (d)) <br /> 23. MONITORING METHOD FOR ALL TANKS AND PIPING APPROVED (CCR 2630-2636) <br /> 24. ALL CONDITIONS MET; FACILITY PERMIT ISSUED (H-S CODE 25284) <br /> COMMENTS: <br /> EH23-006 9/95 <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.